Zone Type Automation Options<br />

Automation options for the zone type configure options for various functions that relate to the control of<br />

automation control settings. The options to control the 24Hr bell are also located in the Automation options.<br />

ZT001 Auto Ctrl<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options (see page 344).<br />

Option 1 - Activate Automation on Alarm<br />

• Enabled the zone type will activate the automation point when the zone assigned this zone type goes in to<br />

alarm.<br />

• Disabled the zone type takes no action on the automation point.<br />

Option 2 - Activate Automation on Restore<br />

• Enabled the zone type will activate the automation point when the zone assigned this zone type goes in to<br />

alarm.<br />

• Disabled the zone type takes no action on the automation point.<br />

Option 3 - Deactivate Automation on Alarm<br />

• Enabled the zone type will deactivate the automation point when the zone assigned this zone type goes in<br />

to alarm.<br />

• Disabled the zone type takes no action on the automation point.<br />

Option 4 - Deactivate Automation on Restore<br />

• Enabled the zone type will deactivate the automation point when the zone assigned the zone type restores.<br />

• Disabled the zone type takes no action on the automation point.<br />

Option 5 - Toggle Automation State on Alarm<br />

• Enabled the zone type will toggle the current state of the automation number that has been assigned.<br />

• Disabled the zone type takes no action on the automation point.<br />

Option 6 - 24HR Audible If Area Armed<br />

• Enabled the zone type will activate the bell PGM if a 24HR alarm is generated when the area is armed.<br />

Please note that this option will be overridden by option 6 and will have no affect.<br />

• Disabled the 24HR will be silent. This will have no affect if option 6 is enabled.<br />

Option 7 - 24HR Always Audible<br />

• Enabled the zone type will always activate the bell PGM for the area if a 24HR tamper alarm occurs. This<br />

option will override option 5 when enabled.<br />

• Disabled the 24HR will be silent.<br />

Option 8 - Reserved<br />

• Reserved do not modify<br />

Enabling/disabling or modifying the settings of reserved options is not recommended.<br />