Exit Options<br />

Exit options for the door type are currently all reserved and perform no function.<br />

DT001 Exit<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options (see page 344).<br />

Option 1, 2, 3, 4, 5, 6, 7 and 8 - Reserved<br />

• Reserved do not modify<br />

Enabling/disabling or modifying the settings of reserved options is not recommended.<br />

Miscellaneous Options<br />

Miscellaneous options for the door type are used to control the REX and REN operation of the door. Use these<br />

settings to prevent the request to exit and request to enter from operating when an area is armed or when a<br />

function is being processed.<br />

DT001 Misc<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options (see page 344).<br />

Option 1 – Disable REX Request To Exit<br />

• Enabled the door will disable the REX (request to exit) operation.<br />

• Disabled the door will allow REX (request to exit) operation.<br />

Option 2 – Disable REN Request To Enter<br />

• Enabled the door will disable the REN (request to enter) operation.<br />

• Disabled the door will allow REN (request to enter) operation.<br />

Option 3, 4, 5, 6, 7 and 8 - Reserved<br />

• Reserved do not modify<br />

Enabling/disabling or modifying the settings of reserved options is not recommended.<br />

Elevator<br />

Each elevator is assigned a unique elevator address. Elevators are used for the control of access by users or to<br />

monitor and control floors in a multi story high rise buildings.<br />

Elevator to<br />

modify: EL001<br />

To access elevator programming, login using a valid code that has access to the elevator programming menu<br />

and then select [MENU, 4, 5, 3]. The screen will then prompt you to "Select a Elevator to modify" requesting<br />

that you enter a elevator number. Type the appropriate 3-digit elevator number or use the [] and [] keys to<br />

scroll the available elevators. When the desired elevator number appears on the screen, press [ENTER] to<br />

program the selected elevator. The maximum number of elevators that can be programmed is limited by your<br />

system's memory and configured profile.<br />

To browse the elevators by name press [ENTER] when prompted for a elevator number to modify and then use<br />