Reader Port 2 Reader Options<br />

Options that relate to the control of reader functions.<br />

RD001 R2 Option<br />

[123-5---]<br />

To modify options, use the keypad as explained in section Entering Data Options (see page 344).<br />

Option 1 - Reader On Unlock and Door Open<br />

• Enabled the reader expander will send card information to the system controller when a door is unlocked or<br />

opened. This option is set by default and should be left set if the door controls areas or time and attendance<br />

events are required from the reader port<br />

• Disabled the reader performs no action when a card is presented and the door is unlock or open.<br />

Option 2 - Send Door Monitoring Events<br />

• Enabled the reader will send door events when the door input is opened or closed. This is enabled by<br />

default but should be disabled on at least one reader port if both reader ports are controlling the same door<br />

(ENTRY and EXIT access control).<br />

• Disabled the reader expander will not send any door events.<br />

Option 3 - LED Follow Lock Status<br />

• Enabled the reader will activate the LED outputs on the reader expander when the lock is opened. This<br />

option DOES not prevent the outputs from being used to display the area armed or alarm status.<br />

• Disabled the reader will not perform any function on the LED outputs.<br />

Option 4 - Bond Sense Input Enable<br />

• Enabled the magnetic bond sense functions. The magnetic bond sense is a contact that indicates if the<br />

magnetic bond between the electromagnet and the clamp is complete. It is used when a separate door<br />

contact and bond sense input are to be used however the generation of door events should be processed<br />

using both inputs.<br />

When opening either of the two contacts open (Door Contact or Bond Sense Input) the door monitoring will<br />

see this as the door being opened and process it accordingly.<br />

• Disabled the reader will not include the bond sense input in the door status processing.<br />

Option 5 - Request To Exit (REX) Enabled<br />

• Enabled the reader expander will generate request to exit events from the REX input on the reader<br />

expander.<br />

• Disabled the keypad will not generate any REX events.<br />

Option 6 - Request To Enter (REN) Enabled<br />

• Enabled the reader expander will generate request to enter events from the REN input on the reader<br />

expander.<br />

Option 7 - Generate Format Error Events<br />

• Enabled the reader expander will send a detailed format error to the system controller if it receives<br />

information from the reader that does not comply with the programmed format. Format errors include bit<br />

count, byte count, parity, checksum and LRC calculation failures.<br />

• Disabled the reader will silently discard any format error. The format error will still be indicated on the reader<br />

input data LED.<br />

Option 8 - Intelligent Reader Tamper<br />

• Enabled the reader expander will assume that the external device has smart messaging that allows a<br />

communication path to be formed from the reading device (Card Reader) to the reader expander.<br />

PRT-CTRL-SE <strong>Protege</strong> <strong>System</strong> <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong> | PRT-CTRL-SE 81