Option 6 – Toggle Zone Control PGM On Restore<br />

• Enabled the zone control PGM will be toggled when the zone goes in to alarm. You can use this option to<br />

activate a PGM on alarm and deactivate on the next alarm. This is ideal for lighting control and automation<br />

applications.<br />

• Disabled the zone type takes no action on the zone control PGM.<br />

Option 7 and 8 - Reserved<br />

• Reserved do not modify<br />

Enabling/disabling or modifying the settings of reserved options is not recommended.<br />

Reporting Code<br />

Each zone type has a default reporting code already assigned which determines the code that is sent to the<br />

central station when an alarm is generated refer to the Contact ID Codes table. However, it is possible to<br />

change the reporting code of the zones to which this zone type is assigned. This is used when using special<br />

reporting formats for example ModBUS Remote uses this to identify special zone points to the remote <strong>Protege</strong><br />

<strong>System</strong> <strong>Controller</strong>.<br />

ZT001 Report<br />

code: 255<br />

To enter a reporting code (000 to 254), use the keypad as explained in section Entering Decimal Numbers (see<br />

page 341) and press [ENTER]. By default the Zone Type Reporting Code is set to 255. Setting a value of 255<br />

uses the default reporting code for the zone assigned.<br />

Control PGM or PGM Group<br />

You can assign a PGM or PGM group to activate whenever a zone type process's an alarm or restore for a<br />

zone. The zone type must have the control PGM options set in the PGM options.<br />

ZT001 Control<br />

pgm: --000:00<br />

To modify the PGM or PGM Group, use the settings as explained in section Entering PGM and PGM Groups<br />

(see page 345).<br />

Control PGM Activation Time<br />

You can override the programmed activation time for a PGM by setting an activation time in the zone type.<br />

ZT001 PGM on<br />

time: 00000 secs<br />

To modify the PGM or PGM Group, use the settings as explained in section Entering PGM and PGM Groups<br />

(see page 345).<br />