To view the IP address of the module press the [] key from this view. If the module is connected over the<br />

RS-485 LAN "---.---.---.---" will be displayed.<br />

To list all offline or online modules refer to the Module Network Functions (see page 207).<br />

Special functions are provided to update, update reset a module and request offline events from a module. In<br />

the case of a update or update reset this occurs for the individual module however pressing the memory key will<br />

start the event request process for the by using a shortcut key directly from the keypad selection screen.<br />

Key<br />

[STAY]<br />

[FORCE]<br />

[MEMORY]<br />

Function<br />

Pressing the [STAY] key will update the zone expander number that is currently displayed in<br />

the module selection window. This will program the module WITHOUT resetting the module.<br />

Pressing the [FORCE] key will update and init the zone expander number that is currently<br />

displayed in the module selection window. This will program the module and then restart the<br />

module.<br />

Pressing the [MEMORY] key will start the system controller in the offline event update mode.<br />

This forces the controller to request all offline events from the Intelligent or Ethernet Reader<br />

Expanders. Pressing the [MEMORY] key while the system controller is already updating the<br />

network or performing other functions the [MEMORY] key will not have any function.<br />

Module Polling Time<br />

The polling time defines how often the Reader Expander module checks in with the <strong>Protege</strong> <strong>System</strong> <strong>Controller</strong>.<br />

If a Reader Expander fails to check in, it triggers its associated communication failure (RDxxx:16) trouble zone<br />

and the trouble zone for a general module communications failure.<br />

To enter a polling time (008 to 250 seconds), use the keypad as explained in section Entering Decimal Numbers<br />

(see page 341) and press [ENTER]. By default the Reader Expander polling time is set to 250 seconds. Setting<br />

a polling time below 60 seconds should only be done for Reader Expanders that are in a non-secure area.<br />

RD001 Polling<br />

time: 250 secs<br />

i<br />

For UL and ULC listed installations you MUST set the polling time to 180 seconds or less.<br />

Reader Expander Module Options<br />

Options that relate to the reader expander module can be set using option entry.<br />

RD001 Module<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options (see page 342).<br />

Option 1 - High Current Charging<br />

• Enabled the high current charging option will set 700mA charging in the power supply system of the reader<br />

expander.<br />

For reader expanders that do not have a power supply this option performs no function.<br />

• Disabled the reader expander will set the standard 350mA charging in the power supply system.<br />

Option 2 - Multiple Reader Connected to Port 1<br />

• Enabled the reader will process the multiplexed reader inputs on Port 1 so that dual readers can be<br />

connected for entry and exit processing. The duplex reader that is connected will always operate as the exit<br />

reader.<br />

• Disabled the reader port 1 interface will operate as a single reader input.<br />

66 PRT-CTRL-SE <strong>Protege</strong> <strong>System</strong> <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong> | PRT-CTRL-SE