Reporting Table<br />

With the size of the <strong>Protege</strong> system the maximum reporting points available in the Contact ID format is easily<br />

exceeded, to allow flexibility a reporting table has been created to allow information to be sent using pre-defined<br />

zone numbers or values. There are 2 predefined configurations for the reporting tables and 8 custom tables that<br />

can be configured for use by any of the services. For information on the custom tables refer to the Table<br />

Configuration section (see page 290).<br />

SV001 Reporting<br />

Table 000<br />

Use the [1] and [3] keys to scroll the reporting tables selection and press [ENTER] to select the reporting table<br />

displayed. For more information about the list control data entry refer to the section List Control Data Entry (see<br />

page 344).<br />

Dialing Attempts<br />

The dialing attempts determine how many times the dialer will attempt to dial a number before failure. This<br />

setting will be overridden by the modem configuration dependent on the country of installation. For UL and ULC<br />

installations this value can not be set above 8 and will be internally restricted if a value is programmed above this<br />

value. The dialing attempts operates in conjunction with the dialing delay setting.<br />

SV001 Dialing<br />

attempts: 008<br />

To modify the dialing attempts (000 to 255, a setting of 000 will result in the default of 8 attempts being used),<br />

use the keypad as explained in section Entering Decimal Numbers (see page 341) and press [ENTER].<br />

Port Open Attempts<br />

The port open attempts determine how many times the service will wait for the modem to become available if<br />

another service is already using modem for communication. This operates in conjunction with the port open<br />

time settings.<br />

SV001 Port open<br />

attempts: 008<br />

To modify the port open attempts (000 to 255, a setting of 000 will result in the default of 8 port attempts being<br />

used), use the keypad as explained in section Entering Decimal Numbers (see page 341) and press [ENTER].<br />

Report Count<br />

The report count if set to a value other than 000 will restrict the service from sending more than the<br />

programmed number of reports to the monitoring station. When using multiple reporting paths that potentially<br />

can report the same event to 2 or more locations the report count should be programmed with an acceptable<br />

limit (Between 8 and 16 is recommended).<br />

SV001 Report<br />

count: 000<br />

To modify the report count (000 to 255, a setting of 000 will result in an unlimited number of reports being able<br />

to be sent), use the keypad as explained in section Entering Decimal Numbers (see page 341) and press<br />

[ENTER].<br />