Option 2 - Invert Door Contacts<br />

• When the option is enabled the door contact input is inverted. This does not affect the zone input<br />

functionality if it is being used.<br />

• Disabled door contact functions normally.<br />

Option 3 - Invert Bond Sensing Input<br />

• Enabled the reader will invert the bond sensing input.<br />

• Disabled bond sensing will operate normally.<br />

Option 4 - Invert Request to Exit Input<br />

• Enabled the reader will invert the request to exit input.<br />

• Disabled REX input will operate normally.<br />

Option 5 - Invert Request to Enter Input<br />

• Enabled the reader will invert the request to enter input.<br />

• Disabled REN input will operate normally.<br />

Option 6 - Request To Exit Operates Always<br />

• Enabled the reader will always allow a request to exit event EVEN if the door is forced open. This will not<br />

restart the forced door or the door alarm operation.<br />

• Disabled REX input will operate only when the door is closed.<br />

Option 7 - Recycle Door Open Too Long Timer On Request To Exit Operation<br />

• Enabled the reader will extend the door open time when the REX is received. The REX must be received<br />

during the normal open time or during the pre-alarm time for the timer to be recycled. Pressing the request<br />

to exit once the door open too long has been entered will require the door to be closed. This option will not<br />

affect the ability for the request to exit action to unlock the door.<br />

• Disabled REX input will not alter the door open time once the door as been opened.<br />

Option 8 - Reserved<br />

• Reserved do not modify<br />

Enabling/disabling or modifying the settings of reserved options is not recommended.<br />

Reader Port 1 Process Options<br />

Options that relate to the extra reader functions.<br />

RD001 R1 Process<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options (see page 344).<br />

Option 1 – Convert Force to Door Open<br />

• Enabled the reader expander will process door forced open events as door open events.<br />

• Disabled the reader will process forced door events as normal.<br />

Option 2 – Disable Red LED Processing<br />

• Enabled the reader expander will not control the Red LED (L2) and the PGM can be used for another<br />

function, this is particularly useful if the attached proximity reader LED's is controlled with one wire.<br />

• Disabled the reader will turn on the Red LED when the door is locked.<br />

Option 3 – Disable Green LED Processing<br />

• Enabled the reader expander will not control the Green LED (L1) and the PGM can be used for another<br />

function, this is particularly useful if the attached proximity reader LED's is controlled with one wire.<br />