Option 4 - Prevent Unlock By Schedule If Inside Area Armed<br />

• Enabled the door will not unlock when the schedule is valid if the inside area is armed. Use this option with<br />

the late open option to prevent false alarms by entry of personal before an area is disarmed. This option<br />

only operates if the option 1 and 2 are not enabled. To prevent unlocking and locking based on schedule<br />

and area status set option 6 and 7 to the required values.<br />

• Disabled the door will unlock normally on schedule.<br />

Option 5 - Prevent Unlock By Schedule If Outside Area Armed<br />

• Enabled the door will not unlock when the schedule is valid if the outside area is armed. Use this option with<br />

the late open option to prevent false alarms by entry of personal before an area is disarmed.<br />

• Disabled the door will unlock normally on schedule.<br />

Option 6 – Area Disarmed AND Schedule Valid Unlock Door<br />

• Enabled the door will unlock if the door unlock schedule is valid "AND" the inside or outside area is<br />

disarmed dependent on the options set for option 4 and 5.<br />

• Disabled the door will perform no AND logic processing for the schedule and area status.<br />

Option 7 - Area Disarmed OR Schedule Valid Unlock Door<br />

• Enabled the door will unlock if the door unlock schedule is valid "OR" the inside or outside area is disarmed<br />

dependent on the options set for option 4 and 5.<br />

If there is no schedule programmed and the door is to follow the area status you must set the OR option to<br />

enable the area status to be processed. You also MUST select an inside or outside area.<br />

• Disabled the door will perform no OR logic processing for the schedule and area status.<br />

Option 8 – Generate REX/REN Access Taken Events<br />

• Enabled the door will generate a Request to Exit (or Enter) event if the door opens while the door is<br />

unlocked from a request to exit. If the door remains closed an Access Not Taken event will be generated<br />

• Disabled no event will be generated.<br />

Extra Options<br />

Extra options include only the user area control option.<br />

DR001 Extra<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options (see page 344).<br />

Option 1 - Update User Area When Door Has No Anti Pass Back<br />

• Enabled the door will update the users current area even if the door is not programmed with card anti pass<br />

back. This can be used to keep track of the user's last area that they entered.<br />

• Disabled the users area will not be modified if the door is not programmed for card anti pass back control.<br />

Option 2 – Prevent Request To Exit If Inside Area Armed<br />

• Enabled the door will deny a request to exit when the inside area has been armed to prevent egress from an<br />

armed area.<br />

• Disabled the request to exit operates during any inside area state.<br />

Option 3 – Enable ADA Lock Output<br />

• Enabled the door will multiply the lock output time by two for any user that has been tagged as an ADA<br />

(American Disabilities Act) user allowing an extended amount of time for access and door left open.<br />

• Disabled the ADA option has no affect on the door lock time.<br />