Option 4 - Bond Sense Input Enable<br />

• Enabled the magnetic bond sense functions. The magnetic bond sense is a contact that indicates if the<br />

magnetic bond between the electromagnet and the clamp is complete. It is used when a separate door<br />

contact and bond sense input are to be used however the generation of door events should be processed<br />

using both inputs.<br />

When opening either of the two contacts open (Door Contact or Bond Sense Input) the door monitoring will<br />

see this as the door being opened and process it accordingly.<br />

• Disabled the reader will not include the bond sense input in the door status processing.<br />

Option 5 - Request To Exit (REX) Enabled<br />

• Enabled the reader expander will generate request to exit events from the REX input on the reader<br />

expander.<br />

• Disabled the keypad will not generate any REX events.<br />

Option 6 - Request To Enter (REN) Enabled<br />

• Enabled the reader expander will generate request to enter events from the REN input on the reader<br />

expander.<br />

• Disabled no action will be taken for the Request To Enter function.<br />

Option 7 - Generate Format Error Events<br />

• Enabled the reader expander will send a detailed format error to the system controller if it receives<br />

information from the reader that does not comply with the programmed format. Format errors include bit<br />

count, byte count, parity, checksum and LRC calculation failures.<br />

• Disabled the reader will silently discard any format error. The format error will still be indicated on the reader<br />

input data LED.<br />

Option 8 - Intelligent Reader Tamper<br />

• Enabled the reader expander will assume that the external device has smart messaging that allows a<br />

communication path to be formed from the reading device (Card Reader) to the reader expander.<br />

i<br />

This allows the reader expander to monitor the reading device and generate a reader missing alarm<br />

(Trouble Zone) if it fails to communicate with the reader expander, allowing the failure to be reported to<br />

a monitoring station. For more information refer to the Nano Prox Programming <strong>Manual</strong>.<br />

• Disabled the intelligent reader mode is disabled.<br />

Reader Port 1 Miscellaneous Options<br />

Options that relate to the miscellaneous reader functions.<br />

RD001 R1 Misc<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options (see page 344).<br />

Option 1 - Disarm Area<br />

• Enabled the reader process will disarm the area designated by the reader type (ENTRY or EXIT) and the<br />

door configuration programmed (If it has an area on the inside or outside assigned).<br />

If this option is enabled and the reader is only used for area control then the area disarmed will be the area<br />

assigned in the area control setting.<br />

• Disabled the reader will not perform any disarm functions.<br />

Option 2 - Allow User Access if Area Armed<br />

• When the option is enabled the user will be granted access based on the access control configuration only<br />

and the area status will not be checked against the user's ability to disarm the area.<br />

74 PRT-CTRL-SE <strong>Protege</strong> <strong>System</strong> <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong> | PRT-CTRL-SE