Keypad Control Door<br />

The keypad control door configured will be is used by the keypad when the door control option is enabled. This<br />

allows a door to be unlocked (similar to a request to exit) by pressing and holding the [FUNCTION] key for two<br />

seconds.<br />

KP001 Ctrl Door<br />

None<br />

Use the [1] and [3] keys to scroll the door selection. For more information about the list control data entry refer<br />

to the section List Control Data Entry (see page 344).<br />

Keypad Auto Logout Time<br />

When the user does not perform any action on the keypad for the time programmed in the logout time the<br />

keypad will automatically log the user out. Programming the option Never Logout should be avoided unless for<br />

training or demonstration purposes.<br />

KP001 Logout<br />

10 Sec<br />

Use the [1] and [3] keys to scroll the auto logout time selection. For more information about the list control data<br />

entry refer to the section List Control Data Entry (see page 344).<br />

Keypad Dual User Entry Time<br />

When the keypad is set to require dual-code entry, the dual-code entry time determines how long the users<br />

have to enter both codes. Dual code entry is primarily used for the control of ATM and Banking applications. For<br />

example, if the time is set to 025 seconds, the dual-code master and dual code provider must successfully<br />

enter their codes within 25 seconds in order to gain access. The dual-code can be overridden only by a user<br />

that has the dual-code override option set (Super User Option).<br />

KP001 Dual<br />

time: 020 secs<br />

To enter a dual user entry time (001 to 250 seconds), use the keypad as explained in section Entering Decimal<br />

Numbers (see page 341) and press [ENTER].<br />

Keypad Invalid Code Lockout Time<br />

If the Lockout option is enabled for the selected keypad and the maximum number of incorrect user codes (PIN<br />

Numbers) is reached (3 Times), the time programmed here defines how long the keypad will be locked out.<br />

During this period, the keypad will display the lockout message and ignore all key entries or login attempts by ay<br />

user. A lockout time of 0 seconds will disable this function regardless of the lockout option setting.<br />

KP001 Invalid<br />

time: 060 secs<br />

To enter a lockout time (001 to 250 seconds), use the keypad as explained in section Entering Decimal<br />

Numbers (see page 341).<br />