Floor Operation Schedule<br />

The floor operation schedule can be assigned to each floor allowing the floor to unlock at the programmed times<br />

within the schedule. A schedule is valid when the time of day falls between any start and end time provided the<br />

day of the week is selected and holidays are not affecting the schedule. For more information on the<br />

programming of the schedule refer to the Schedule Programming section (see page 279).<br />

FL001 Schedule<br />

None<br />

Use the [1] and [3] keys to scroll the schedule selection and press [ENTER] to select the schedule displayed.<br />

For more information about the list control data entry refer to the section List Control Data Entry (see page 344).<br />

A schedule selection of NONE will disable the floor unlock schedule and no action will be taken on the floor.<br />

Floor Area<br />

The floor area defines which area is on the inside of this floor. This is used to prevent a user from gaining access<br />

to a floor when the area is armed and they can not disarm it as well as automatically disarming the area when<br />

the floor is accessed. Using the floor and area control integrates the two systems and is an ideal solution for<br />

false alarm prevention.<br />

FL001 Area<br />

None<br />

Use the [1] and [3] keys to scroll the floor area selection and press [ENTER] to select the floor area displayed.<br />

For more information about the list control data entry refer to the section List Control Data Entry (see page 344).<br />

General Options<br />

General options configure the floor for various operational modes and functions.<br />

EL001 General<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options (see page 344).<br />

Option 1 – Unlock Elevator Floor Late To Open<br />

• Enabled the floor will only be unlocked on schedule if a valid access has been made to the selected floor.<br />

i<br />

Unlock late to open will only operate if the elevator is configured for destination reporting and a<br />

PRT-PX16-DRI is present.<br />

• Disabled the floor will follow the floor schedule if programmed.<br />

Option 2 – Validate Schedule Every Minute<br />

• Enabled the floor state will be checked against the schedule every minute and change state accordingly.<br />

• Disabled the floor will unlock at the start time of the schedule and lock at the end time. The floor will not be<br />

controlled during this time by the schedule.<br />

Option 3 – Follow Area Status<br />

• Enabled the floor will follow the status of the area. If the area is armed the floor will lock and if the area is<br />

disarmed the floor will unlock.<br />

• Disabled the floor will not follow the area status.<br />

Option 4, 5, 6, 7 and 8 - Reserved<br />

• Reserved do not modify<br />

Enabling/disabling or modifying the settings of reserved options is not recommended.<br />