Count PGM Pulse ON Time<br />

The count PGM pulse on time is used to make the PGM output pulse on and off when activated. The value<br />

entered here must be greater than 0 and is in increments of 100ms. For example setting 10 will pulse the unit on<br />

for 1 second and then off for the programmed time set in the pulse off section.<br />

AR001 Count<br />

time: 000 on<br />

To modify the pulse on time (000 to 255 100ms Increments), use the keypad as explained in section Entering<br />

Decimal Numbers (see page 341) and press [ENTER]. Both the on and off pulse settings must have a value<br />

greater than 000 for this feature to operate.<br />

Count PGM Pulse OFF Time<br />

The count PGM pulse off time is used to make the PGM output pulse on and off when activated. The value<br />

entered here must be greater than 0 and is in increments of 100ms. For example setting 10 will pulse the unit off<br />

for 1 second and then on for the programmed time set in the pulse on section.<br />

AR001 Count<br />

time: 000 off<br />

To modify the pulse on time (000 to 255 100ms Increments), use the keypad as explained in section Entering<br />

Decimal Numbers (see page 341) and press [ENTER]. Both the on and off pulse settings must have a value<br />

greater than 000 for this feature to operate.<br />

Defer PGM or PGM Group<br />

You can assign a PGM or PGM group to activate whenever the area begins the defer warning cycle and is<br />

about to arm. The defer warning time is programmed in the defer time setting. The defer PGM or PGM Group<br />

will be deactivated when the area begins the arming cycle or when the defer time is canceled by a user.<br />

AR001 Defer arm<br />

pgm: --000:00<br />

To modify the Defer PGM or PGM Group, use the settings as explained in section Entering PGM and PGM<br />

Groups (see page 345).<br />

Defer PGM Pulse ON Time<br />

The defer PGM pulse on time is used to make the PGM output pulse on and off when activated. The value<br />

entered here must be greater than 0 and is in increments of 100ms. For example setting 10 will pulse the unit on<br />

for 1 second and then off for the programmed time set in the pulse off section.<br />

AR001 Defer arm<br />

time: 000 on<br />

To modify the pulse on time (000 to 255 100ms Increments), use the keypad as explained in section Entering<br />

Decimal Numbers (see page 341) and press [ENTER]. Both the on and off pulse settings must have a value<br />

greater than 000 for this feature to operate.<br />

124 PRT-CTRL-SE <strong>Protege</strong> <strong>System</strong> <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong> | PRT-CTRL-SE