Access Level Assignment<br />

The access level determines what rights this user will have in the <strong>Protege</strong> system. For more information on the<br />

programming of the access level refer to the Access Level Programming section (see page 40). Each user can<br />

be assigned four different access levels, when a user requests a certain action the <strong>Protege</strong> system checks each<br />

of the access levels in order until it finds one that has rights to perform the requested action. Each access level<br />

can also be assigned an independent start and end time.<br />

UN00001 Access<br />

*Access Lvl 001<br />

Use the [1] and [3] keys to scroll the access level selection and press [ENTER] to select the access level<br />

displayed. For more information about the list control data entry refer to the section List Control Data Entry (see<br />

page 344) .<br />

Access Level 1 Start Date<br />

Setting the access level start date will disable the access level for this user until 00:00 on this date. If a start<br />

time is also set the access level will be disabled until that time has past on this date.<br />

UN00001 Axs1 Sta<br />

date: --/--/----<br />

Use the numerical keys to enter a valid date and then press [ENTER] to program the date. If you do not<br />

program a time in the following section the access level will expire at midnight on the date that is programmed.<br />

For more information about entering the date information refer to the section Date and Time Data Entry (see<br />

page 342).<br />

If you do not enter a valid date an error message will be shown, pressing the [STAY] key will allow you to clear<br />

your entry or set the default value.<br />

Access Level 1 Start Time<br />

Setting the access level start time will disable the access level for the user until this time has past. If both the<br />

start time and date are set then the access level will remain disabled until the date and time has past. If only<br />

the time is set then the access level will be disabled until this time has past and will then remain enabled until<br />

either the access level end time expires or until the midnight of that day.<br />

Use this feature to program cards for temporary employees, trade people or contractors. This feature can also<br />

be used for membership processing to prevent access once the membership period has expired.<br />

UN00001 Axs1 Sta<br />

time: --:--<br />

Use the numerical keys to enter a valid time in a 24HR format and then press [ENTER] to program the time. If<br />

you do not program a time in the following section the user will expire at midnight on the date that is<br />

programmed. For more information about entering the date information refer to the section Date and Time Data<br />

Entry (see page 342) .<br />

If you do not enter a valid time an error message will be shown, pressing the [STAY] key will allow you to clear<br />

your entry.<br />

24 PRT-CTRL-SE <strong>Protege</strong> <strong>System</strong> <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong> | PRT-CTRL-SE