Keypad Smoke Detector Reset PGM<br />

The PGM that is programmed as the keypad smoke detector reset PGM will be activated when a user press's<br />

the [CLEAR + ENTER] keys together. The selected PGM should have a time programmed of 5 to 10 seconds,<br />

for information on setting a PGM activation time refer to the PGM Programming section (see page 109).<br />

KP001 Smoke<br />

pgm: -----:--<br />

To enter a smoke detector PGM, use the keypad as explained in section Entering PGM and PGM Groups (see<br />

page 345).<br />

Keypad Module Options<br />

Options that relate to the keypad module can be set using option entry.<br />

KP001 Module<br />

[1-34----]<br />

To modify options, use the keypad as explained in section Entering Data Options (see page 344).<br />

Option 1 - Beep on Key Press<br />

• Enabled the keypad will NOT beep when a key is pressed.<br />

• Disabled the keypad will generate a beep tone each time a key is pressed.<br />

Option 2 - Zone Duplex Operation<br />

• Enabled the keypad will enable the Duplex Zone option making it possible to connect four zone inputs to<br />

the keypad.<br />

• Disabled the keypad will use the standard zone configuration settings.<br />

Option 3 - Keypad Lockout<br />

• Enabled the keypad will lockout any user activity for the programmed lockout time if three invalid PIN<br />

numbers are entered. This option will have no affect if the lockout time is programmed to 0 seconds.<br />

• Disabled the keypad will perform no action on an invalid PIN.<br />

Option 4 - Keypad Lockout<br />

• Enabled the keypad will allow the [CLEAR] / [X] key to disable the beeper on the keypad. You must hold the<br />

key for two seconds.<br />

• Disabled the [CLEAR] / [X] will not perform any action.<br />

Option 5, 6, 7 and 8 - Reserved<br />

• Reserved do not modify<br />

Enabling/disabling or modifying the settings of reserved options is not recommended.<br />

Keypad Display Options<br />

The following options determine which screens will be displayed when the keypad is offline. The keypad is offline<br />

when no valid user code (PIN) has been entered. By default the keypad will display the system message<br />

programmed in to the panel configuration settings.<br />

KP001 Display<br />

[1-------]<br />

To modify options, use the keypad as explained in section Entering Data Options (see page 344).<br />

If all message options are disabled the LCD Keypad will display a standard system is ready message on the<br />

display.<br />