Door Control and Status Display<br />

Each door will display the status of the door inputs that are controlling the door and the state of the lock output<br />

that is controlled by the door configuration.<br />

*Door 001<br />

(Closed)(Locked)<br />

Use the [] and [] keys to scroll the available doors while in the view screen, press the [1] key to unlock the<br />

door for the programmed unlock time, press the [2] key to lock the door, press the [3] key to activate the door<br />

latched, press the [4] key to change the door lockdown state and press the [5] key to cancel the door<br />

lockdown. Press the [] to return to the Door selection display.<br />

The display will show the door input states listed below.<br />

CLOSED<br />

OPEN<br />

FORCED<br />

PREALM<br />

LEFTOP<br />

Door is closed<br />

Door is open<br />

Door is forced open<br />

Door is in a pre-alarm open condition<br />

Door has been left open<br />

The display will show the door lock states listed below.<br />

LOCKED<br />

ACCESS<br />

SCHED<br />

TIMED<br />

LATCH<br />

ENTRY<br />

EXIT<br />

MENU<br />

AREA<br />

FIRE<br />

LD-ALL<br />

LD-ENT<br />

LD-EXT<br />

LD-E+E<br />

Lock PGM is deactivated<br />

Lock PGM is activated by a user entry<br />

Lock PGM is activated by schedule<br />

Lock PGM is activated for time period by manual control<br />

Lock PGM is activated latched by manual control<br />

Lock PGM is activated request to enter<br />

Lock PGM is activated request to exit<br />

Lock PGM is activated keypad control<br />

Lock PGM is activated by area<br />

Lock PGM is activated by fire control programmable function<br />

Door is in Lockdown and will only unlock for a super user<br />

Door is in Lockdown with Entry Allowed<br />

Door is in Lockdown with Exit Allowed<br />

Door is in Lockdown with Entry and Exit Allowed<br />

Profile Configuration<br />

Profiles configure the local onboard and expanded memory (if it is present) with the number of supported<br />

records (Users, Events, Doors ...). To enter the profile menu select [MENU, 4, 8, 3] you can then scroll the<br />

menu for the available options.<br />

Changing Profiles<br />

To change profiles login using a valid installer code and then select [MENU, 4, 8, 3, 1]. The screen displays<br />

"Select profile" as shown in the following example.<br />

Select profile<br />

Standard<br />

Eight profiles are provided that allow the configuration of numerous record structures and setups, it is also<br />

possible to customize the number of records that the controller will function with by selecting the custom profile.<br />