Communications Port Number<br />

The communications interface port defines which serial port the controller will use for communication when<br />

sending the serial printer output.<br />

SV001 Port<br />

Ext Port 1<br />

Use the [1] and [3] keys to scroll the communication ports and press [ENTER] to select the operating mode<br />

displayed. For more information about the list control data entry refer to the section List Control Data Entry (see<br />

page 344).<br />

Communications Port Speed<br />

The communications port speed defines the baud rate at which the serial printer service will operate. The default<br />

value for serial printer is 9600 bits per second. If the speed or configuration is different adjust this setting to suit<br />

the host configuration.<br />

SV001 Speed<br />

9600<br />

Use the [1] and [3] keys to scroll the communication port speed options and press [ENTER] to select the speed<br />

displayed. For more information about the list control data entry refer to the section List Control Data Entry (see<br />

page 344).<br />

Communications Port Parity<br />

The communications port parity defines the parity configuration for the communication with the serial printer. By<br />

default this is set to None however can be adjusted to suit the needs of the host that is connected.<br />

SV001 Parity<br />

None<br />

Use the [1] and [3] keys to scroll the communication parity options and press [ENTER] to select the parity<br />

displayed. For more information about the list control data entry refer to the section List Control Data Entry (see<br />

page 344).<br />

Area Events Group<br />

The area events group defines which areas events will be sent through the serial printer service. Setting an area<br />

group to None (Default) will result in all areas being sent. Setting an area group with a specific group of areas will<br />

filter the area related events based on the areas configured in the group.<br />

SV001 Area Grp<br />

None<br />

Use the [1] and [3] keys to scroll the available area groups and press [ENTER] to select the area group that is<br />

displayed. For more information about the list control data entry refer to the section List Control Data Entry (see<br />

page 344).<br />