Zone Status Display<br />

When the zone is selected the name of the zone will be displayed on the top line and the state of the zone will<br />

be shown on the bottom line.<br />

Warehouse PIR<br />

is TAMPERED<br />

Use the [] and [] keys to scroll the available zones while in the view screen or press the [] to return to the<br />

zone selection. Pressing the [ARM] key will toggle the display between the name and the zone identification.<br />

Each zone is assigned a unique identification that uses the <strong>Protege</strong> Notation.<br />

CP001:01 Zone<br />

is TAMPERED<br />

The display will show the zone state and will depend on the resistor configuration option programmed for the<br />

zone that is being viewed. The possible states that can be displayed are:<br />

OPEN<br />

CLOSED<br />

SHORT<br />

TAMPERED<br />

Zone is opened.<br />

Zone is closed.<br />

Zone is shorted out or a wiring fault has occurred.<br />

Zone wiring is cut or faulty.<br />

By default the zone name will be shown on the top line of the screen however if no name is programmed or the<br />

name is blank it may be desirable to view the device and address of the module that the zone is connected to.<br />

To view the input in the system it is connected on press the [ARM] key, the [ARM] key can be pressed<br />

repeatedly to toggle between the two display options.<br />

Viewing Trouble Zones<br />

To access the trouble zone view menu login using a valid installer code and then select [MENU, 4, 8, 2, 1, 2].<br />

The screen displays "Trouble zone to view" as shown in the following example.<br />

Trouble zone to<br />

view: CP001:01<br />

Type the appropriate module type, module address and trouble zone number or use the [] and [] keys to<br />

scroll the available trouble zones. When the desired trouble zone number appears on the screen, press [ENTER]<br />

to view the selected trouble zone number.<br />

When selecting a trouble zone the trouble zone address is entered using the Module Type, Module Address and<br />

the number of the zone, this is called <strong>Protege</strong> Object Notation.<br />

Information on the <strong>Protege</strong> Object Notation and how it applies to programmable objects within the <strong>Protege</strong><br />

<strong>System</strong> refer to the Object Notation Section (see page 338).<br />

Trouble Zone Status Display<br />

When the trouble zone is selected the name of the trouble zone will be displayed on the top line and the state of<br />

the trouble zone will be shown on the bottom line. The Trouble Zone names are not able to be modified and<br />

assigned by default.<br />

CP001 Tamper<br />

is OPEN<br />

Use the [] and [] keys to scroll the available trouble zones while in the view screen or press the [] to return<br />

to the trouble zone selection. Pressing the [ARM] key will toggle the display between the name and the trouble<br />

zone identification. Each zone is assigned a unique identification that uses the <strong>Protege</strong> Notation.<br />

The display will show the trouble zone states as detailed below.<br />

OPEN<br />

CLOSED<br />

Zone is opened.<br />

Zone is closed.<br />