Zone Inputs<br />

To access the zone programming, login using the valid installer code and then select [MENU, 4, 2, 1] for zone<br />

programming, [MENU, 4, 2, 2] for trouble zone programming and [MENU, 4, 2, 3] for zone type programming.<br />

The Zones menu enables you to set up and program all the zones in your system.<br />

i<br />

Zones and trouble zones can only be programmed when the areas they are assigned to and the<br />

area's 24hr processing are disarmed/disabled, refer to Arm and Disarm Operations. If the area or the<br />

associated 24hr processing is armed/enabled, you can only view the screens, but not modify the<br />

information they contain. A warning will be shown on entering the zone programming indicating that<br />

the zone is only able to be viewed and the records are locked.<br />

When selecting a Zone or Trouble Zone the zone address is entered using the Module Type, Module Address<br />

and the number of the zone or trouble zone, this is called <strong>Protege</strong> Object Notation. Information on the <strong>Protege</strong><br />

Object Notation and how it applies to programmable objects within the <strong>Protege</strong> <strong>System</strong> refer to the Object<br />

Notation section (see page 338).<br />

For the alarm memory to display a trouble zone when a tamper/short occurs, the 24hr processing must be<br />

enabled for at least one of the area's that the zone has been assigned in.<br />

Zone<br />

To access the Zone programming menu login using a valid installer code and then select [MENU, 4, 2, 1]. The<br />

screen displays "Select zone to modify" as shown in the following example.<br />

Select zone to<br />

modify: CP001:01<br />

Every time you press the Enter key, the next screen appears. The different screens are described in the<br />

following sub-sections. Programming zones allows you to configure which zones belong in to areas and the<br />

options used when the zone is activated.<br />

When programming zones some options are processed at the module, for these options to operate correctly a<br />

network update must be performed and the device that the zone is located on must be registered and online.<br />

Updating modules can be accessed by selecting [MENU, 4, 8, 1, 3], you can also check the status of your<br />

modules by selecting [MENU, 4, 8, 1, 1] for all modules presently offline and [MENU, 4, 8, 1, 2] for all online<br />

modules. For more information refer to the Advanced Menu Section (see page 207).<br />

90 PRT-CTRL-SE <strong>Protege</strong> <strong>System</strong> <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong> | PRT-CTRL-SE