20.01.2015 Views

Protege System Controller Reference Manual

Protege System Controller Reference Manual

Protege System Controller Reference Manual

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Zone Extra Options<br />

Additional options for setting up the Zone Type.<br />

ZT001 Extra<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options (see page 344).<br />

Option 1 - Always Log Zone Event<br />

• Enabled, if the 'Log to Event Buffer' option in the Zone options is deselected, then over-ride this and log the<br />

Event anyway.<br />

• Disabled, log the event only as required by other settings<br />

Option 2 - Retrigger PGM time<br />

• Enabled, each time the Zone activates it will restart the associated PGMs time out counter.<br />

• Disabled, the Zone will not retrigger the PGM time.<br />

Options 3, 4, 5, 6, 7 and 8 - Reserved<br />

• Reserved do not modify<br />

Enabling/disabling or modifying the settings of reserved options is not recommended.<br />

Zone Control PGM Options<br />

Zone PGM options for the zone type, configure how the zone type will process the activation of the PGM<br />

assigned to the zone (not the zone type).<br />

ZT001 Zone Ctrl<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options (see page 344).<br />

Option 1 – Use Zone Type PGM Time<br />

• Enabled the zone will activate the PGM timed (if a time is programmed) and use the PGM Time Set in the<br />

Zone Type. If the zone type does not have a time programmed no time will be used.<br />

• Disabled the zone will activate using the PGM timer if it is set to a value greater than 0.<br />

Option 2 - Activate Control PGM On Alarm<br />

• Enabled the zone type will activate the zone control PGM when the zone assigned generates an alarm.<br />

• Disabled the zone type takes no action on the control PGM.<br />

Option 3 - Activate Control PGM On Restore<br />

• Enabled the zone type will activate the zone control PGM when the zone assigned restores from an alarm.<br />

• Disabled the zone type takes no action on the zone control PGM.<br />

Option 4 - Deactivate Control PGM On Alarm<br />

• Enabled the zone type will de-activate the zone control PGM when the zone assigned generates an alarm.<br />

• Disabled the zone type takes no action on the zone control PGM.<br />

Option 5 - Deactivate Control PGM On Restore<br />

• Enabled the zone type will de-activate when the zone control PGM assigned restores from an alarm.<br />

• Disabled the zone type takes no action on the zone control PGM.<br />

108 PRT-CTRL-SE <strong>Protege</strong> <strong>System</strong> <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong> | PRT-CTRL-SE