Bypass<br />

To access the bypass menu, login using a valid code that is allowed bypass menu access and then select<br />

[MENU, 7]. You can then browse the bypass menu and select the bypass that you want to perform on your<br />

<strong>Protege</strong> <strong>System</strong>.<br />

Bypass Menu<br />

The bypass menu consists of 2 entries that can be scrolled to using the [] and [] arrow or selected directly<br />

using the shortcut keys shown in the figure below.<br />

Bypassing Zones<br />

To bypass zones select [MENU, 7, 1] then using the [] and [] arrows to scroll the available zones. A zone<br />

can be bypassed by pressing the [1] key to bypass the zone and then the [2] key to remove the zone bypass. A<br />

zone can also be bypassed in latch mode by pressing the [3] key. If a zone is bypassed normally [1] the zone<br />

bypass will be removed the next time the area disarms, please not all areas that have this zone programmed<br />

must disarm for the bypass to be removed.<br />

• Select the bypass zone menu [MENU, 7, 1]. The display will show the first zone in the system.<br />

Warehouse PIR<br />

is not BYPASSED<br />

• If a normal bypass is required press the [1] key the zone will then toggle state and the display will show the<br />

bypassed message below.<br />

Warehouse PIR<br />

is BYPASSED<br />

• Pressing the [2] key will remove the bypass and pressing the [3] key will bypass the zone in a latched state<br />

requiring that the bypass is removed manually before it will operate again.<br />

i<br />

The <strong>Protege</strong> <strong>System</strong> also allows you to search for a zone based on the zone text that is programmed.<br />

To use the search functionality press the [MEMORY] key.<br />

Bypassing Trouble Zones<br />

To bypass trouble zones select [MENU, 7, 2] then using the [] and [] arrows to scroll the available trouble<br />

zones. A trouble zone can be bypassed by pressing the [1] key to bypass the trouble zone and then the [2] key<br />

to remove the trouble zone bypass. A trouble zone can also be bypassed in latch mode by pressing the [3] key.<br />

If a trouble zone is bypassed normally [1] the trouble zone bypass will be removed the next time the area<br />

disarms, please note that all areas that have this trouble zone programmed must disarm for the bypass to be<br />

removed.<br />

• Select the bypass trouble zone menu [MENU, 7, 2]. The display will show the first trouble zone in the<br />

system.<br />