Zone Number Contact ID Code Reporting Point Number<br />

CP001:28 415 (Service 4 Stopped) 528<br />

CP001:29 140 (General Alarm) 529<br />

| | | | | | | | | | |<br />

CP001:64 140 (General Alarm) 564<br />

In the above table a reporting code of 999 indicates that the zone is outside the maximum zones that can be<br />

reported in some cases the zone number will reflect the module address that the zone was activated from to aid<br />

in service.<br />

Keypad Zones<br />

The keypad will report trouble zones from 1 to 8 on the first 2 modules, all modules above address KP002 will<br />

be reported using the default code of 999.<br />

Zone Number Contact ID Code Reporting Point Number<br />

KP001:01 145 (Module Tamper) 565<br />

KP001:02 302 (Low Voltage) 566<br />

KP001:03 120 (Panic 1+3) 567<br />

KP001:04 121 (Duress Code) 568<br />

KP001:05 423 (Forced Access) 569<br />

KP001:06 426 (Door Open) 570<br />

KP001:07 461 (Invalid Code Lockout) 571<br />

KP001:08 143 (Module Offline) 572<br />

KP002:01 145 (Module Tamper) 573<br />

KP002:02 302 (Low Voltage) 574<br />

| | | | | | | |<br />

KP002:08 143 (Module Offline) 580<br />

KP003:01 145 (Module Tamper) 999<br />

| | | | | | | |<br />

KP250:04 143 (Module Offline) 999<br />

In the above table a reporting code of 999 indicates that the zone is outside the maximum zones that can be<br />

reported for the module type.<br />

16 Zone Expander<br />

The 16 zone expander will report trouble zones from 1 to 16 on the first 20 modules, all modules above address<br />

ZX020 will be reported using the default code of 999.<br />

Zone Number Contact ID Code Reporting Point Number<br />

ZX001:01 145 (Module Tamper) 581<br />

ZX001:02 301 (AC Loss) 582<br />

ZX001:03 302 (Low <strong>System</strong> Battery) 583<br />

ZX001:04 312 (Auxiliary Fuse) 584<br />