Zone Number Description Type Group<br />

ZXxxx:08 Bell 2 Over Current Bell/PGM Fault General<br />

ZXxxx:09 Reserved * *<br />

ZXxxx:10 Reserved * *<br />

ZXxxx:11 Reserved * *<br />

ZXxxx:12 Reserved * *<br />

ZXxxx:13 Reserved * *<br />

ZXxxx:14 Reserved * *<br />

ZXxxx:15 Reserved * *<br />

ZXxxx:16 Module Offline Module Offline <strong>System</strong><br />

In the above table a '*' indicates that the trouble zone will not generate a system trouble as by default it is not<br />

assigned a trouble type or group. A trouble group and type can be assigned if required but is not recommended<br />

for reserved zones.<br />

When using the reference table the zone expander address should be used in place of the 'xxx'.<br />

PGM Expander<br />

The following lists the trouble zones that operate on the PGM expander module. The PGM expander module<br />

has 8 trouble zones.<br />

Zone Number Description Type Group<br />

PGxxx:01 Module Tamper <strong>System</strong> Tamper <strong>System</strong><br />

PGxxx:02 AC failure Power Fault General<br />

PGxxx:03 Low Battery Power Fault General<br />

PGxxx:04 Aux Failure Power Fault General<br />

PGxxx:05 Relay Supply Failure Power Fault General<br />

PGxxx:06 Reserved * *<br />

PGxxx:07 Reserved * *<br />

PGxxx:08 Module Offline Module Offline <strong>System</strong><br />

In the above table a '*' indicates that the trouble zone will not generate a system trouble as by default it is not<br />

assigned a trouble type or group. This can be done if required but is not recommended.<br />

When using the reference table the PGM expander address should be used in place of the 'xxx'.<br />

Reader Expander<br />

The following lists the trouble zones that operate on the reader expander module. The reader expander module<br />

has 16 trouble zones.<br />

Zone Number Description Type Group<br />

RDxxx:01 Module Tamper <strong>System</strong> Tamper <strong>System</strong><br />

RDxxx:02 AC failure Power Fault General<br />

RDxxx:03 Low Battery Power Fault General<br />

RDxxx:04 Aux Failure Power Fault General<br />

324 PRT-CTRL-SE <strong>Protege</strong> <strong>System</strong> <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong> | PRT-CTRL-SE