Reader Port 2 Reading Format<br />

The reading format is used to inform the reader expander what type of card readers are connected to the reader<br />

port one. The reader expander supports nearly all publicly available protocols and some special protocols. Any<br />

26 or 37 bit card reader that conforms to the standard format specification will work on the PRT-RDI2 Reader<br />

Expander.<br />

RD001 R2 Format<br />

26 Bit<br />

Use the [1] and [3] keys to scroll the available card reader format settings. For more information about the list<br />

control data entry refer to the section List Control Data Entry (see page 344).<br />

For a list of supported formats refer to the Reader Expander Format Table (see page 67).<br />

Reader Port 2 Secondary Reading Format<br />

The secondary reading format is used to program an alternate format for the reader expander and has the same<br />

options as the standard reader selection. The secondary format will only be used if the first format can not<br />

decode the card information that is received by the reader interface.<br />

RD001 R2 Format<br />

None<br />

Use the [1] and [3] keys to scroll the available card reader format settings. For more information about the list<br />

control data entry refer to the section List Control Data Entry (see page 344).<br />

For a list of supported formats refer to the Reader Expander Format Table (see page 67).<br />

Reader Port 2 Reader Type<br />

The reader type informs the reader expander which location of the door the reader is installed that is connected<br />

to the reader expander port two. The reader expander uses this information to pass the correct direction of<br />

travel to the door control functions. For an access door this should be set to ENTRY reader.<br />

When using the reader with a door that controls an inside or outside area or is used for card or key global<br />

anti-passback the ENTRY and EXIT configuration must be set correctly.<br />

RD001 R2 Type<br />

ENTRY Reader<br />

Use the [1] and [3] keys to scroll the available reader type settings. For more information about the list control<br />

data entry refer to the section List Control Data Entry (see page 344).<br />

Arming Mode<br />

ENTRY Reader<br />

EXIT Reader<br />

Operation<br />

The reader is located on the outside of the door and is used to enter in to the area that is<br />

being protected by the door. This is the default setting and should be set for all general<br />

access doors (single reader)<br />

The reader is located on the inside of the door and is used to exit out of the area that is<br />

being protected by the door.<br />

If the reader expander is configured for multiplex reader mode the multiplexed reader is<br />

ALWAYS the EXIT reader.<br />