Secondary Telephone Number<br />

A secondary telephone number when programmed will be used when the schedule of the telephone number<br />

that is being programmed is not valid. The schedule of the secondary telephone number must be valid or set to<br />

none.<br />

PN001 Secondary<br />

None<br />

Use the [1] and [3] keys to scroll the secondary telephone number selection and press [ENTER] to select the<br />

telephone number displayed. For more information about the list control data entry refer to the section List<br />

Control Data Entry (see page 344). Programming a secondary telephone number that uses the current<br />

telephone number being edited will perform no function.<br />

Telephone Number<br />

Program the telephone number that you want to assign to this telephone number entry.<br />

PN001 Number<br />

Use the numeric keys [0] to [9] to enter the telephone number. When the number has been programmed press<br />

the [ENTER] key. To clear the telephone number displayed press the [DISARM] key.<br />

When using a telephone number that requires a number to be dialled before gaining an outside line program the<br />

individual number or series of numbers in to a telephone number and call this 'PABX Access'. When<br />

programming the service or function that requires the telephone number you will also be able to select a<br />

telephone number for PABX access.<br />

Sequential Dialing Attempts<br />

Sequential dialing is used by default and results in the reporting phone numbers programmed in the service<br />

being dialed sequentially. In the following example, a service is programmed with a two telephone numbers<br />

(Phone 1 and Phone 2) and a backup telephone number. The number of dialing attempts is set to 8 and the Use<br />

Alternate Dialing Method option is disabled.<br />

Success After 5th Dialing Attempt With Phone Number 1<br />

In the following example, the <strong>Controller</strong> was able to communicate with the central station with the programmed<br />

phone number 1 on the 5th attempt.<br />

Dial Attempt Number Phone Number Dialed Result<br />

1 Phone Number 1 Fail<br />

2 Phone Number 1 Fail<br />

3 Phone Number 1 Fail<br />

4 Phone Number 1 Fail<br />

5 Phone Number 1 Success (Report OK)<br />

Success After 1st Dialing Attempt With Back Up Phone<br />

In the following example, the <strong>Controller</strong> was able to communicate with the central station only after the backup<br />

phone number was used. This resulted in the opening of the reporting failure trouble zone as a result of the<br />

reporting failure. This is subsequently sealed on the next valid report from the backup phone number.<br />

Dial Attempt Number Phone Number Dialed Result<br />

1 Phone Number 1 Fail<br />

204 PRT-CTRL-SE <strong>Protege</strong> <strong>System</strong> <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong> | PRT-CTRL-SE