Elevator Group<br />

The elevator group selects the elevators to control as a result of the action being performed by the<br />

programmable function.<br />

FN001 Elev Grp<br />

None<br />

Use the [1] and [3] keys to scroll the action types until you reach the elevator group that you want to control and<br />

then press [ENTER] to proceed to the next programmable option for the door control function. For more<br />

information about the list control data entry refer to the section List Control Data Entry (see page 344).<br />

Floor Group<br />

The floor group selects the floors that will be activated on all of the elevators in the elevator group as a result of<br />

the action being performed by the programmable function.<br />

FN001 Floor Grp<br />

None<br />

Use the [1] and [3] keys to scroll the floor groups until you reach the required group and then press [ENTER] to<br />

proceed to the next programmable option for the elevator control function. For more information about the list<br />

control data entry refer to the section List Control Data Entry (see page 344).<br />

Token Unlock Time<br />

The token unlock time is the period of time the floor group will be activated for as a result of the action by the<br />

programmable function.<br />

FN001 Token<br />

time: 010 secs<br />

Elevator Control Mode<br />

The control mode selects how the floor group will be controlled. This allows a door to be unlocked for the token<br />

time, unlock latched or unlocked in the fire alarm mode.<br />

FN001 Door Mode<br />

Menu Timed<br />

Use the [1] and [3] keys to scroll the door control mode until you reach the setting that you want to use and then<br />

press [ENTER] to proceed to the next programmable option for the door control function. For more<br />

information about the list control data entry refer to the section List Control Data Entry (see page 344).<br />

Door Mode<br />

Menu Timed<br />

Menu Latched<br />

Fire Control<br />

Description<br />

The Floor Group will be unlocked for the token time that is programmed for the<br />

programmable function. Use this mode when you want to unlock the door for defined<br />

time. The floors will lock after the token time has expired.<br />

The floors will be latched in the unlocked state and will remain unlocked until controlled<br />

from:<br />

• An LCD Keypad<br />

• <strong>Protege</strong> <strong>System</strong> Management Suite<br />

• Scheduled Action<br />

• Area Status<br />

• A Programmable function.<br />

The door will be latched in the fire control unlock state and will remain unlocked until<br />

controlled from:<br />

• An LCD Keypad<br />

252 PRT-CTRL-SE <strong>Protege</strong> <strong>System</strong> <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong> | PRT-CTRL-SE