Use this option when multiple areas are assigned the same child area that needs to be controlled with a<br />

specific disarming and arming order. This effectively allows an OR and AND operation to be done on the<br />

child area.<br />

• Disabled the child area, if option 3 is enabled, will be armed when the parent (this) area arms.<br />

Option 5 - Disarm Child Area<br />

• Enabled the child area will only be disarmed when the parent (this) area disarms.<br />

• Disabled the child area will not be disarmed and option 6 performs no function.<br />

Option 6 - Disarm Child Area Only If All Disarmed<br />

• Enabled the child area will only be disarmed if ALL the areas that the child area are assigned are disarmed.<br />

Use this option when multiple areas are assigned the same child area that needs to be controlled with a<br />

specific disarming and arming order. This effectively allows an OR and AND operation to be done on the<br />

child area.<br />

• Disabled the child area, if option 5 is enabled, will be disarmed when the parent (this) area arms.<br />

Option 7 - Prevent None Force Zone On Unattended Arming<br />

• Enabled the area will be prevented from arming if a zone that is not a force enabled zone is open when the<br />

area is armed in an unattended mode (Software Control, Reader Control or Remote Control).<br />

• Disabled the area will arm regardless of the zone type configuration used.<br />

Option 8 - Area Used For Loiter Control<br />

• Enabled the area will control the users that access the area for a period of time assigned to the loiter control<br />

time. If a user breaches the allocated time the user will be set to the area programmed in the loiter area<br />

setting.<br />

• Disabled the area does not operate as a loiter area.<br />

Area Reporting Options<br />

Reporting options for the area include the settings for the reporting events and some specific options for the<br />

control counting options.<br />

AR001 Report<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options (see page 344).<br />

Option 1 - Report Closing (Arming) Area<br />

• Enabled the area will generate a reportable event that can be directed to a monitoring station.<br />

• Disabled the area will not generate an event when it is closed (armed).<br />

Option 2 - Report Opening (Disarming) Area<br />

• When enabled the area will generate a reportable event that can be sent to a monitoring station.<br />

• Disabled the area will not generate an event when it is opened (disarmed).<br />

Option 3 - Report Control of the 24HR Tamper Area<br />

• Enabled the area will report both an opening (Disabled) or closing (Enabling) of the 24HR section of this<br />

area.<br />

• Disabled the 24HR Tamper Area will not report any enable or disable messages.<br />

Option 4 - Report Bypassed Zones<br />

• Enabled the area will report all zones that are bypassed once it completes the arming process.<br />

• Disabled the area will not report any bypass zones.<br />