1534 Klaus-Dirk Henning<br />

vent condensation and back to the blower V-2. At the end <strong>of</strong> the adsorption step the bed contains<br />

10-30% solvent and 1-2% water.<br />

There are various ways to remove the water separately and to recover a solvent containing<br />

between 0.1 and 1.5 % water (Table 22.1.10).<br />

Table 22.1.10. Process conditions and water content in the solvent (After references<br />

32,33)<br />

Water in the<br />

raw solvent<br />

Investment<br />

cost, %<br />

Heat needed,<br />

kWh/kg S<br />

Power,<br />

kWh/kg S<br />

Basic process with molsieve beds 0.1 100 2.2 1.0<br />

Chiller instead <strong>of</strong> molsieve 1.5 91 1.5 1.0<br />

Chiller and 1 carbon bed 0.4 - 1.0 93 1.1 1.0<br />

Chiller, and 1 carbon bed molsieve 0.1 96 1.1 1.0<br />

Using molecular sieves<br />

Beds <strong>of</strong> molecular sieves are used to recover a solvent with 0.1%. This process requires<br />

around 2-2.5 kWh heat/kg <strong>of</strong> recovered solvent. Regeneration loop pressure drops<br />

are high, because <strong>of</strong> the additional molsieve beds and valves.<br />

Separate condensation <strong>of</strong> water<br />

Initially, when regenerative heating <strong>of</strong> the bed starts, very little solvent is desorbed,<br />

but much <strong>of</strong> the water (about 87%) is desorbed. The circulating gas is first passed through a<br />

cooler and then a separate chiller for the condensation or freezing <strong>of</strong> the water. Subsequently<br />

the gas is passed to the chiller where the water is condensed or frozen. From 1 to<br />

1.8% water is recovered. This process is simpler than the molecular sieves process.<br />

Two separate chillers<br />

Two separate chillers are used in another adsorption process which <strong>of</strong>fers further substantial<br />

improvements. A third activated carbon bed is added so that while two <strong>of</strong> the beds<br />

are being regenerated one <strong>of</strong> these is being cooled and transferring its heat to the other bed<br />

which is being heated. This not only gives excellent heat recovery but also provides a means<br />

<strong>of</strong> reducing the water content <strong>of</strong> the recovered solvent. The cooled bed absorbs the water vapor<br />

from the gas stream coming from chiller. This dry gas stream is transported to the bed<br />

which is being heated and the desorbed solvent from the heated bed remains dry. <strong>Solvents</strong><br />

recovered at this stage contain only 0.4 to 0.5% water. Solvent which is removed from the<br />

bed being cooled is readsorbed on the bed being heated.<br />

The process, which is patented, brings important benefits <strong>of</strong> regeneration gas flow<br />

rates. Such low flow rates mean that the process requires less heat, less refrigeration and a<br />

lower cost regeneration loop. The overall efficiency is high because the low residual solvent<br />

loading <strong>of</strong> the regenerated beds leads to increased solvent recovery.<br />

Two separate chillers plus molecular sieve bed<br />

A two chiller system with a molecular sieve bed has to be regenerated only about once<br />

per week, since most <strong>of</strong> the water is removed in the chiller and readsorbed on the cooled carbon<br />

bed. This process <strong>of</strong>fers a high solvent recovery rate giving a solvent with only 0.1 %<br />

water at greatly reduced heat consumption, lower investment, and higher solvent recovery<br />

rate.