10.3 Solvent effects based on pure solvent scales 589<br />

Scheme III.<br />

ize the scale by assigning a zero value to tetramethylsilane and a unity value to water, using<br />

the following expression:<br />

N<br />

ET =(ET(solvent) -ET(TMS))/(ET(water) -ET(TMS))=(ET(solvent) -30.7) / 32.4 [10.3.6]<br />

N<br />

The corresponding ET values (between 0 and 1) allow one to rank all solvents studied.<br />

This is no doubt the most comprehensive solvent scale (it encompasses more than 300 solvents)<br />

and also the most widely used at present. 1,13 The probe (1) exhibits solubility problems<br />

in non-polar solvents that the authors have overcome by using a tert-butyl derivative<br />

(2). One serious hindrance to the use <strong>of</strong> this type <strong>of</strong> probe is its high basicity (pKa = 8.64 49 ),<br />

which raises problems with acid solvents.<br />

10.3.3.4 The Py scale <strong>of</strong> Dong and Winnick<br />

The Py scale 50 is based on the ratio between the intensity <strong>of</strong> components<br />

(0,0) I1 and (0,2) I3 <strong>of</strong> the fluorescence <strong>of</strong> monomeric pyrene (3) in various<br />

solvents. It was initially established from 95 solvents 50 and spans values<br />

from 0.41 for the gas phase to 1.95 for DMSO. This scale is primarily used<br />

in biochemical studies, which usually involve fluorescent probes. However,<br />

it poses problems arising largely from the difficulty <strong>of</strong> obtaining precise values<br />

<strong>of</strong> the above-mentioned intensity ratio; this has resulted in divergences<br />

among Py values determined by different laboratories. 51 One further hindrance<br />

is that the mechanism via which low-polar solvents enhance the intensity <strong>of</strong> symmetry-forbidden<br />

vibronic transitions through a reduction in local symmetry is poorly<br />

understood. 52<br />

10.3.3.5 The Z scale <strong>of</strong> Kosower<br />

The Z scale 53,54<br />

is based on the strong solvatochromism <strong>of</strong> the 1-ethyl-4-<br />

(methoxycarbonyl)pyridinium iodide ion-pair (4) and defined by the position (in kcal mol -1 )<br />

<strong>of</strong> the maximum <strong>of</strong> its first absorption band, which has marked intermolecular charge-transfer<br />

connotations according to Scheme IV (the excited state <strong>of</strong> the chromophore is much less