Control keypad 99(110)<br />

7<br />

Enter the edit mode by pushing the right arrow menu button. The present value shown starts to<br />

blink. Use the Browser buttons to change the amount of retries. Accept the change with the Enter<br />

button or return to the previous level with the left arrow menu button<br />

See Figure 7-23 for the procedure of changing the value.<br />

7.3.6.8 System info<br />

In the System info submenu (S6.8) frequency drive-related hardware and software information as<br />

well as operation-related information, can be found.<br />

Total counters (S6.8.1)<br />

In the Total counters page (S6.8.1) is information related to the frequency drive operation times,<br />

i.e. the total numbers of MWh, operation days and operation hours passed so far. Unlike the<br />

counters in the Trip counters menu, these counters cannot be reset.<br />

Note! The operation time counter (days and hours) runs anytime the power is on.<br />

Page Counter Example<br />

C6.8.1.1 MWh counter<br />

C6.8.1.2 Operation day counter Value on display is 1.013. the drive has<br />

operated for 1 year and 13 days<br />

C6.8.1.3 Operation hour counter Value on display is 7:05:16. The drive has<br />

operated for 7 hours 5 minutes and 16 seconds.<br />

Table 7-7. Counter pages<br />

Trip counters (S6.8.2)<br />

Trip counters (menu S6.8.2) are counters the values of which can be reset i.e. restored to zero.<br />

The following resettable counters are available:<br />

Note! The trip counters run only when the motor is running.<br />

Page<br />

Counter<br />

T6.8.2.1 MWh counter<br />

T6.8.2.3 Operation day counter<br />

T6.8.2.4 Operation hour counter<br />

Table 7-8. Resettable counters<br />

The counters can be reset on pages 6.8.2.2 (MWh counter reset) and 6.8.2.5 (Operation time<br />

reset).<br />

Example: To reset the operation counters:<br />

Automation and Control Solutions<br />

Honeywell<br />

Honeywell Limited-Honeywell Limitée<br />

1985 Douglas Drive North 35 Dynamic Drive<br />

Golden Valley, MIN 55422 Scarborough, Ontario <strong>63</strong>-<strong>2600</strong>-1<br />

MIV 4Z9<br />

www.honeywell.com