76 Multi-purpose Control Application Honeywell<br />

6.6.4.5 Analogue input 4 (Control keypad: Menu M2 G2.2.5)<br />

Code Parameter Min Max Unit Default Cust ID Note<br />

P2.2.5.1<br />

AI4 signal<br />

selection<br />

0 0.1 152<br />

P2.2.5.2 AI4 filter time 0,00 10,00 s 0,00 153 0=No filtering<br />

P2.2.5.3 AI4 signal range 0 3 1 154<br />

0=0…100%<br />

1=20…100%<br />

2= -10V…+10V<br />

3=Custom range<br />

P2.2.5.4<br />

AI4 custom minimum<br />

-160,00<br />

setting<br />

160,00 % 20,00 155<br />

P2.2.5.5<br />

AI4 custom<br />

maximum setting<br />

-160,00 160,00 % 100,00 156<br />

P2.2.5.6 AI4 signal inversion 0 1 0 162<br />

0=Not inverted<br />

1=Inverted<br />

Table 6-10. Analogue input 4 parameters, G2.2.5<br />

6.6.4.6 Free analogue input, signal selection (Keypad: Menu M2 G2.2.6)<br />

Code Parameter Min Max Unit Default Cust ID Note<br />

P2.2.6.1<br />

Scaling of current<br />

limit<br />

0 5 0 399<br />

0=Not used<br />

1=AI1<br />

2=AI2<br />

3=AI3<br />

4=AI4<br />

5=FB limit scaling ID46<br />

P2.2.6.2<br />

Scaling of DC-braking<br />

current<br />

0 5 0 400 Scaling from 0 to ID507<br />

P2.2.6.3<br />

Reducing of acc./dec.<br />

Scaling from Ramp Time<br />

0 5 0 401<br />

times<br />

to 0,1 s<br />

P2.2.6.4<br />

Reducing of torque<br />

supervision limit<br />

0 5 0 402 Scaling from 0 to ID348<br />

P2.2.6.5 Scaling of torque limit 0 5 0 485<br />

Scaling from 0 to (ID609<br />

(<strong>NXS</strong>) or ID1287 (NXP))<br />

NXP drives only<br />

P2.2.6.6<br />

Scaling of generator<br />

torque limit<br />

0 5 0 1087 Scaling from 0 to ID1288<br />

P2.2.6.7<br />

Scaling of motoring<br />

power limit<br />

0 5 0 179 Scaling from 0 to ID1289<br />

P2.2.6.8<br />

Scaling of generator<br />

power limit<br />

0 5 0 1088 Scaling from 0 to ID1290<br />

Table 6-11. Free analogue input signal selection, G2.2.6<br />

Automation and Control Solutions<br />

Honeywell<br />

Honeywell Limited-Honeywell Limitée<br />

1985 Douglas Drive North 35 Dynamic Drive<br />

Golden Valley, MIN 55422 Scarborough, Ontario <strong>63</strong>-<strong>2600</strong>-1<br />

MIV 4Z9<br />

www.honeywell.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!