Control keypad 93(110)<br />

7<br />

READY<br />

READY<br />

I/Oterm<br />

I/Oterm<br />

S6.4 S6.4.1<br />

ParamComparison<br />

C1C3<br />

OR<br />

Set1<br />

S6.4.1<br />

Set1<br />

0<br />

READY<br />

I/Oterm<br />

P1P6<br />

READY<br />

I/Oterm<br />

P2.1.2= 50.0<br />

20.0 Hz<br />

READY<br />

I/Oterm<br />

P2.1.2= 50.0<br />

20.0 Hz<br />

enter<br />

EDIT VALUE<br />

CONFIRM CHANGE<br />

Figure 7-13. Parameter comparison<br />

7.3.6.5 Security<br />

NOTE: The Security submenu is protected with a password. Store the password in a safe place!<br />

Password (S6.5.1)<br />

The application selection can be protected against unauthorised changes with the Password<br />

function (S6.5.1).<br />

By default, the password function is not in use. To activate the function, enter the edit mode by<br />

pushing the right arrow menu button. A blinking zero appears in the display and a password can<br />

be set with the Browser buttons. The password can be any number between 1 and 65535.<br />

Note The password can be set by digits. In the edit mode, push the right arrow menu button once<br />

again and another zero appears on the display. First set the units. Push the left arrow menu<br />

button and set the tens etc. Finally, confirm the password setting with the Enter button. After this,<br />

wait until the Timeout time (P6.6.3) (see page 96) has expired before the password function is<br />

activated.<br />

If the applications or the password itself are changed the system will request the current<br />

password. The password will be entered with the Browser buttons.<br />

READY<br />

READY<br />

I/Oterm<br />

I/Oterm<br />

enter<br />

I/Oterm<br />

S6.5.1 S6.5.1 S6.5.1<br />

Password<br />

Not in use<br />

Password<br />

0<br />

OR:<br />

Password<br />

00<br />

READY<br />

enter<br />

Figure 7-14. Password setting<br />

Automation and Control Solutions<br />

Honeywell<br />

Honeywell Limited-Honeywell Limitée<br />

1985 Douglas Drive North 35 Dynamic Drive<br />

Golden Valley, MIN 55422 Scarborough, Ontario <strong>63</strong>-<strong>2600</strong>-1<br />

MIV 4Z9<br />

www.honeywell.com