Control keypad 95(110)<br />

7<br />

Multimonitoring items (P6.5.4)<br />

Honeywell alpha-numeric keypad features a display where the user can monitor even three actual<br />

values at the same time (see chapter 7.3.1 and chapter Monitoring values in the manual of the<br />

application you are using). On page P6.5.4 of the System Menu you can define if it is possible for<br />

the operator to replace the values monitored with other values. See below.<br />

READY<br />

READY<br />

I/Oterm<br />

I/Oterm<br />

I/Oterm<br />

P6.5.4 P6.5.4 P6.5.4<br />

enter<br />

Multimon. items<br />

ChangeEnable<br />

Multimon. items<br />

ChangeEnable<br />

Figure 7-17. Enabling the change of multimonitoring items<br />

READY<br />

Multimon. items<br />

ChangeDisable<br />

7.3.6.6 Keypad settings<br />

Further customization of the frequency drive operator interface can be undertaken in the Keypad<br />

settings submenu under the System menu.<br />

Locate the Keypad settings submenu (S6.6). Under the submenu, there are four pages (P#)<br />

associated with the keypad operation:<br />

Default page (P6.6.1)<br />

READY<br />

I/Oterm<br />

I/Oterm<br />

S6.6 P6.6.1<br />

Keypad settings<br />

P1P5<br />

Figure 7-18. Keypad settings submenu<br />

This menu allows the user to set the location (page) to which the display automatically moves as the<br />

Timeout time (see below) has expired or as the power is switched on to the keypad.<br />

If the Default Page value is 0 the function is not activated, i.e. the last displayed page remains on the<br />

keypad display. Press the right arrow menu button once to enter the edit mode. Change the number of the<br />

Main menu with the Browser buttons. Pressing the right arrow menu button once again enables editing of<br />

the number of the submenu/page. If the page to move to by default is at the third level repeat the<br />

procedure. Confirm the new default page value with the Enter button. Return to the previous step anytime<br />

by pushing the left arrow menu button.<br />

0.<br />

READY<br />

Default page<br />

I/Oterm<br />

READY<br />

I/Oterm<br />

READY<br />

I/Oterm<br />

READY<br />

enter<br />

CONFIRM CHANGE<br />

Default page<br />

0.<br />

Default page<br />

Default page<br />

0. 1.<br />

REPEAT TO SET<br />

DEFAULT SUBMENU/PAGE<br />

CANCEL<br />

Figure 7-19. Default page function<br />

Automation and Control Solutions<br />

Honeywell<br />

Honeywell Limited-Honeywell Limitée<br />

1985 Douglas Drive North 35 Dynamic Drive<br />

Golden Valley, MIN 55422 Scarborough, Ontario <strong>63</strong>-<strong>2600</strong>-1<br />

MIV 4Z9<br />

www.honeywell.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!