208 Description of Parameters Honeywell<br />

1300 Speed controller f0 point 6 (2.6.27.26)<br />

The speed level in Hz below which the speed controller gain is equal to par. ID1299.<br />

1301 Speed controller f1 point 6 (2.6.27.25)<br />

The speed level in Hz above which the speed controller gain is equal to par. ID613.<br />

From the speed defined by par. ID1300 to speed defined by par. ID1301, the speed<br />

controller gain changes linearly from par. ID1299 to ID613 and vice versa.<br />

1304 Window positive 6 (2.10.12)<br />

Defines size of window to positive direction.<br />

1305 Window negative 6 (2.10.11)<br />

Defines size of window to negative direction.<br />

1306 Window positive Off limit 6 (2.10.14)<br />

Defines speed controller positive off limit when the speed controller brings speed back to<br />

window.<br />

1307 Window negative Off limit 6 (2.10.13)<br />

Defines speed controller negative off limit when the speed controller brings speed back<br />

to window.<br />

1311 Speed error filter PC 6 (2.6.27.33)<br />

Filter time constant for speed reference and actual speed error.<br />

Automation and Control Solutions<br />

Honeywell<br />

Honeywell Limited-Honeywell Limitée<br />

1985 Douglas Drive North 35 Dynamic Drive<br />

Golden Valley, MIN 55422 Scarborough, Ontario <strong>63</strong>-<strong>2600</strong>-1<br />

MIV 4Z9<br />

www.honeywell.com