Honeywell Pump and Fan Control Application 109<br />

P2.2.1.14<br />

P2.2.1.15<br />

P2.2.1.16<br />

P2.2.1.17<br />

Actual value 2<br />

maximum scale<br />

Motor potentiometer<br />

ramp time<br />

Motor potentiometer<br />

frequency reference<br />

memory reset<br />

Motor potentiometer<br />

PID reference<br />

memory reset<br />

–<br />

1600,0<br />

1600,0 % 100,0 339 100=No maximum scaling<br />

0,1 2000,0 Hz/s 10,0 331<br />

0 2 1 367<br />

0 2 0 370<br />

P2.2.1.18<br />

B reference scale,<br />

minimum<br />

0,00 320,00 Hz 0,00 344<br />

P2.2.1.19<br />

B reference scale,<br />

maximum<br />

0,00 320,00 Hz 0,00 345<br />

Table 7-4. Input signals, Basic settings<br />

7.5.3.2 Analogue input 1 (Control keypad: Menu M2 G2.2.2)<br />

0=No reset<br />

1=Reset if stopped or<br />

powered down<br />

2=Reset if powered down<br />

0=No reset<br />

1=Reset if stopped or<br />

powered down<br />

2=Reset if powered down<br />

0=Scaling off<br />

>0=Scaled min. value<br />

0=Scaling off<br />

>0=Scaled max. value<br />

Code Parameter Min Max Unit Default Cust ID Note<br />

P2.2.2.1<br />

AI1 signal<br />

selection<br />

0 A.1 377<br />

P2.2.2.2 AI1 filter time 0,00 10,00 s 0,10 324 0=No filtering<br />

P2.2.2.3 AI1 signal range 0 2 0 320<br />

0=Signal range 0-100%*<br />

1=Signal range 20-100%*<br />

2=Custom range<br />

P2.2.2.4<br />

AI1 custom<br />

minimum setting<br />

-160,00 160,00 % 0,00 321<br />

P2.2.2.5<br />

AI1 custom<br />

maximum setting<br />

-160,00 160,00 % 100,00 322<br />

P2.2.2.6 AI1 signal inversion 0 1 0 323<br />

0=Not inverted<br />

1=Inverted<br />

Table 7-5. Input signals, Analogue input 1<br />

7.5.3.3 Analogue input 2 (Control keypad: Menu M2 G2.2.3)<br />

Code Parameter Min Max Unit Default Cust ID Note<br />

P2.2.3.1 AI2 signal selection 0 A.2 388<br />

P2.2.3.2 AI2 filter time 0,00 10,00 s 0,10 329 0=No filtering<br />

P2.2.3.3 AI2 signal range 0 2 1 325<br />

0=0—20 mA*<br />

1=4—20 mA*<br />

2=Customised*<br />

P2.2.3.4<br />

AI2 custom minimum<br />

setting<br />

-160,00 160,00 % 0,00 326<br />

P2.2.3.5<br />

AI2 custom maximum<br />

setting<br />

-160,00 160,00 % 100,00 327<br />

P2.2.3.6 AI2 inversion 0 1 0 328<br />

Table 7-6. Input signals, Analogue input 2<br />

0=Not inverted<br />

1=Inverted<br />

*Remember to place jumpers of block X2 accordingly.<br />

See NX User's <strong>Manual</strong>, chapter 6.2.2.2<br />

Automation and Control Solutions<br />

Honeywell<br />

Honeywell Limited-Honeywell Limitée<br />

1985 Douglas Drive North 35 Dynamic Drive<br />

Golden Valley, MIN 55422 Scarborough, Ontario <strong>63</strong>-<strong>2600</strong>-1<br />

MIV 4Z9<br />

www.honeywell.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!