28 Local/Remote Control Application Honeywell<br />

P2.2.15<br />

P2.2.16<br />

P2.2.17<br />

P2.2.18<br />

P2.2.19<br />

P2.2.20<br />

P2.2.21<br />

P2.2.22<br />

P2.2.23<br />

Place B Start/Stop<br />

logic selection<br />

Place A Reference<br />

scaling minimum<br />

value<br />

Place A Reference<br />

scaling maximum<br />

value<br />

Place B Reference<br />

scaling minimum<br />

value<br />

Place B Reference<br />

scaling maximum<br />

value<br />

Free analogue input,<br />

signal selection<br />

Free analogue input,<br />

function<br />

Motor potentiometer<br />

ramp time<br />

Motor potentiometer<br />

frequency reference<br />

memory reset<br />

0 6 0 3<strong>63</strong><br />

0,00 320,00 Hz 0,00 303<br />

0,00 320,00 Hz 0,00 304<br />

0,00 320,00 Hz 0,00 364<br />

0,00 320,00 Hz 0,00 365<br />

0 2 0 361<br />

0 4 0 362<br />

0,1 2000,0 Hz/s 10,0 331<br />

0 2 1 367<br />

P2.2.24 Start pulse memory 0 1 0 498<br />

Table 3-4. Input signals, G2.2<br />

DIN4 DIN5<br />

0 Start fwd Start rvs<br />

1 Start/Stop Rvs/Fwd<br />

2 Start/Stop Run<br />

3 Start pulse enable<br />

4 Fwd* Stop pulse<br />

5 Start*/Stop Rvs*<br />

6 Start*/Stop Rvs/Fwd<br />

Run<br />

enable<br />

Selects the frequency that<br />

corresponds to the min.<br />

reference signal<br />

Selects the frequency that<br />

corresponds to the max.<br />

reference signal<br />

0,00 = No scaling<br />

>0 = scaled max. value<br />

Selects the frequency that<br />

corresponds to the min.<br />

reference signal<br />

Selects the frequency that<br />

corresponds to the max.<br />

reference signal<br />

0,00 = No scaling<br />

>0 = scaled max. value<br />

0=Not used<br />

1=U in (analogue volt. input<br />

2=I in (analogue curr. input)<br />

0=No function<br />

1=Reduces current limit<br />

(par. 2.1.5)<br />

2=Reduces DC braking<br />

current<br />

3=Reduces accel. and<br />

decel. times<br />

4=Reduces torque<br />

supervision limit<br />

0=No reset<br />

1=Reset if stopped or<br />

powered down<br />

2=Reset if powered down<br />

0=Run state not copied<br />

1=Run state copied<br />

* = Rising edge required to start<br />

** = Remember to place jumpers of block X2 accordingly.<br />

See the product's User's <strong>Manual</strong>.<br />

Automation and Control Solutions<br />

Honeywell<br />

Honeywell Limited-Honeywell Limitée<br />

1985 Douglas Drive North 35 Dynamic Drive<br />

Golden Valley, MIN 55422 Scarborough, Ontario <strong>63</strong>-<strong>2600</strong>-1<br />

MIV 4Z9<br />

www.honeywell.com