Honeywell Multi-purpose Control Application 77<br />

6.6.4.7 Digital inputs (Control keypad: Menu M2 G2.2.4)<br />

Code Parameter Min Default Cust ID Note<br />

P2.2.7.1 Start signal 1 0 A.1 403<br />

P2.2.7.2 Start signal 2 0 A.2 404<br />

P2.2.7.3 Run enable 0 0.2 407 Motor start enabled (cc)<br />

P2.2.7.4 Reverse 0 0.1 412<br />

P2.2.7.5 Preset speed 1 0 0.1 419<br />

P2.2.7.6 Preset speed 2 0 0.1 420<br />

P2.2.7.7 Preset speed 3 0 0.1 421<br />

P2.2.7.8<br />

Motor potentiometer<br />

reference DOWN<br />

0 0.1 417<br />

P2.2.7.9<br />

Motor potentiometer<br />

reference UP<br />

0 0.1 418<br />

Direction forward (oc)<br />

Direction reverse (cc)<br />

See preset speeds in Basic<br />

Parameters (G2.1)<br />

Mot.pot. reference decreases<br />

(cc)<br />

Mot.pot. reference increases<br />

(cc)<br />

P2.2.7.10 Fault reset 0 0.1 414 All faults reset (cc)<br />

P2.2.7.11 External fault (close) 0 0.1 405 Ext. fault displayed (cc)<br />

P2.2.7.12 External fault (open) 0 0.2 406 Ext. fault displayed (oc)<br />

P2.2.7.13 Acc/Dec time selection 0 0.1 408<br />

Acc/Dec time 1 (oc)<br />

Acc/Dec time 2 (cc)<br />

P2.2.7.14 Acc/Dec prohibit 0 0.1 415 Acc/Dec prohibited (cc)<br />

P2.2.7.15 DC braking 0 0.1 416 DC braking active (cc)<br />

P2.2.7.16 Jogging speed 0 A.4 413<br />

Jogging speed selected for<br />

frequency reference (cc)<br />

P2.2.7.17 AI1/AI2 selection 0 0.1 422<br />

P2.2.7.18 Control from I/O terminal 0 0.1 409<br />

Force control place to I/O<br />

terminal (cc)<br />

P2.2.7.19 Control from keypad 0 0.1 410<br />

Force control place to<br />

keypad (cc)<br />

P2.2.7.20 Control from fieldbus 0 0.1 411<br />

Force control place to<br />

fieldbus (cc)<br />

P2.2.7.21<br />

Parameter set 1/set 2<br />

Closed cont.=Set 2 is used<br />

0 0.1 496<br />

selection<br />

Open cont.=Set 1 is used<br />

P2.2.7.22 Motor control mode 1/2 0 0.1 164<br />

Closed cont.=Mode 2 is used<br />

Open cont.=Mode 1 is used<br />

See par 2.6.1, 2.6.12<br />

NXP drives only<br />

P2.2.7.23 Cooling monitor 0 0.2 750 Used with liquid-cooled unit<br />

P2.2.7.24<br />

External brake<br />

Monitoring signal from<br />

0 0.2 1210<br />

acknowledge<br />

mechanical brake<br />

P2.2.7.25 Prevention of startup 0 0.2 1420 Safety switch input<br />

P2.2.7.26 Enable inching 0 0.1 532 Enables Inching function<br />

P2.2.7.27 Inching reference 1 0 0.1 530<br />

Inching reference 1. This will<br />

start the drive<br />

P2.2.7.28 Inching reference 2 0 0.1 531<br />

Inching reference 2. This will<br />

start the drive<br />

P2.2.7.29 Reset encoder counter 0 0.1 1090<br />

Reset monitoring signals,<br />

shaft rounds and angle<br />

P2.2.7.30 Emergency stop 0 0.2 1213<br />

P2.2.7.31 Master Follower mode 2 0 0.1 1092<br />

P2.2.7.32<br />

Input switch<br />

acknowledgement<br />

0 0.2 1209<br />

Table 6-12. Digital input signals, G2.2.4<br />

cc = closing contact<br />

oc = opening contact<br />

Automation and Control Solutions<br />

Honeywell<br />

Honeywell Limited-Honeywell Limitée<br />

1985 Douglas Drive North 35 Dynamic Drive<br />

Golden Valley, MIN 55422 Scarborough, Ontario <strong>63</strong>-<strong>2600</strong>-1<br />

MIV 4Z9<br />

www.honeywell.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!