150 Description of Parameters Honeywell<br />

359 PID controller minimum limit 5 (2.2.30)<br />

360 PID controller maximum limit 5 (2.2.31)<br />

With these parameters you can set the minimum and maximum limits for the PID<br />

controller output.<br />

Limit setting: –1600.0% (of f max ) < par. ID359 < par. ID360 < 1600.0% (of f max ).<br />

These limits are of importance for example when you define the gain, I-time and D-time<br />

for the PID controller.<br />

361 Free analogue input, signal selection 34 (2.2.20, 2.2.17)<br />

Selection of input signal of a free analogue input (an input not used for reference signal):<br />

0 = Not in use<br />

1 = Voltage signal U in<br />

2 = Current signal I in<br />

362 Free analogue input, function 34 (2.2.21, 2.2.18)<br />

This parameter is used for selecting a<br />

function for a free analogue input signal:<br />

Torque limit<br />

0 = Function is not in use<br />

100%<br />

Par. ID107<br />

1 = Reduces motor current limit (ID107)<br />

This signal will adjust the maximum<br />

motor current between 0 and max. limit<br />

set with ID107. See Figure 8-26.<br />

0 V<br />

0 mA<br />

4 mA<br />

Custom<br />

Signal range<br />

10 V<br />

20 mA<br />

20 mA<br />

Custom<br />

Analogue<br />

input<br />

NX12K61<br />

Figure 8-26. Scaling of max. motor current<br />

2 = Reduces DC braking current.<br />

DC braking current can be reduced with<br />

the free analogue input signal between<br />

zero current and the current set with<br />

the parameter ID507. See Figure 8-27.<br />

100%<br />

Par. ID507<br />

DC-braking<br />

current<br />

0,4 x I H<br />

Free analogue<br />

input<br />

0<br />

Signal range<br />

NX12K58<br />

Figure 8-27. Reduction of DC braking current<br />

Automation and Control Solutions<br />

Honeywell<br />

Honeywell Limited-Honeywell Limitée<br />

1985 Douglas Drive North 35 Dynamic Drive<br />

Golden Valley, MIN 55422 Scarborough, Ontario <strong>63</strong>-<strong>2600</strong>-1<br />

MIV 4Z9<br />

www.honeywell.com