Honeywell Pump and Fan Control Application 113<br />

7.5.4.2 Limit settings (Control keypad: Menu M2 G2.3.2)<br />

Code Parameter Min Max Unit Default Cust ID Note<br />

P2.3.2.1<br />

P2.3.2.2<br />

P2.3.2.3<br />

P2.3.2.4<br />

P2.3.2.5<br />

P2.3.2.6<br />

P2.3.2.7<br />

P2.3.2.8<br />

P2.3.2.9<br />

P2.3.2.10<br />

P2.3.2.11<br />

P2.3.2.12<br />

P2.3.2.13<br />

P2.3.2.14<br />

Output frequency<br />

limit 1 supervision<br />

Output freq. limit 1;<br />

Supervised value<br />

Output frequency<br />

limit 2 supervision<br />

Output freq. limit 2;<br />

Supervised value<br />

Torque limit<br />

supervision<br />

Torque limit<br />

supervision value<br />

Reference limit<br />

supervision<br />

Reference limit<br />

supervision value<br />

External<br />

brake-off delay<br />

External<br />

brake-on delay<br />

FC temperature<br />

supervision<br />

FC temperature<br />

supervised value<br />

Supervised<br />

analogue input<br />

Analogue input limit<br />

supervision<br />

0 2 0 315<br />

0,00 320,00 Hz 0,00 316<br />

0 2 0 346<br />

0,00 320,00 Hz 0,00 347<br />

0 2 0 348<br />

-300,0 300,0 % 100,0 349<br />

0 2 0 350<br />

0,0 100,0 % 0,0 351<br />

0,0 100,0 s 0,5 352<br />

0,0 100,0 s 1,5 353<br />

0 2 0 354<br />

–10 100 °C 40 355<br />

0 3 0 372<br />

0 2 0 373<br />

Analogue input<br />

P2.3.2.15<br />

0,00 100,00 % 0,00 374<br />

supervised value<br />

Table 7-11. Output signals, Limit settings<br />

0=No limit<br />

1=Low limit supervision<br />

2=High limit supervision<br />

0=No limit<br />

1=Low limit supervision<br />

2=High limit supervision<br />

0=Not used<br />

1=Low limit supervision<br />

2=High limit supervision<br />

0=Not used<br />

1=Low limit<br />

2=High limit<br />

0=Not used<br />

1=Low limit<br />

2=High limit<br />

0=AI1<br />

1=AI2<br />

0=No limit<br />

1=Low limit supervision<br />

2=High limit supervision<br />

Automation and Control Solutions<br />

Honeywell<br />

Honeywell Limited-Honeywell Limitée<br />

1985 Douglas Drive North 35 Dynamic Drive<br />

Golden Valley, MIN 55422 Scarborough, Ontario <strong>63</strong>-<strong>2600</strong>-1<br />

MIV 4Z9<br />

www.honeywell.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!