Control keypad 101(110)<br />

7<br />

READY<br />

I/Oterm<br />

Standard<br />

D1D3<br />

READY<br />

I/Oterm<br />

Version<br />

2.01<br />

S6.8.4<br />

READY<br />

I/Oterm<br />

Applications<br />

A1 A7<br />

Figure 7-25. Applications info page<br />

A6.8.4.1<br />

Basic<br />

READY<br />

I/Oterm<br />

D1 D3<br />

READY<br />

I/Oterm<br />

Application id<br />

NXFIFF01<br />

In the Applications information page, push the Menu button right to enter the Application pages of<br />

which there are as many as there are applications loaded into the frequency drive. Locate the<br />

application you want information about with the Browser buttons and then enter the Information<br />

pages with the Menu button right. Use again the Browser buttons to see the different pages<br />

Hardware (S6.8.5)<br />

The Hardware information page provides information on the following hardware-related topics:<br />

Page<br />

Content<br />

6.8.5.1 Nominal power of the unit<br />

6.8.5.2 Nominal voltage of the unit<br />

6.8.5.3 Brake chopper<br />

6.8.5.4 Brake resistor<br />

Table 7-11. Hardware information pages<br />

Expander boards (S6.8.6)<br />

Information about the basic and option boards connected to the control board can be found in the<br />

Expanders submenu (see Chapter 6.2).<br />

You can check the status of each slot by entering the board submenu with the right arrow menu<br />

button and using the Browser buttons to choose the board whose status you wish to check. Push<br />

the right arrow menu button again to display the status of the board. The keypad will also display<br />

the program version of the respective board when either one of the Browser buttons is pushed.<br />

If no board is connected to the slot the text 'no board' will be shown. If a board is connected to a<br />

slot but the connection is somehow lost the text 'no conn.' is displayed. See Chapter 6.2 for more<br />

information.<br />

For more information on the expander board-related parameters, see Chapter 7.3.7.<br />

Automation and Control Solutions<br />

Honeywell<br />

Honeywell Limited-Honeywell Limitée<br />

1985 Douglas Drive North 35 Dynamic Drive<br />

Golden Valley, MIN 55422 Scarborough, Ontario <strong>63</strong>-<strong>2600</strong>-1<br />

MIV 4Z9<br />

www.honeywell.com