8136 Working with Menu 61:Menu 62:Menu 63:Menu 64:Menu 65:Menu 66:Menu 67:Menu 68:Menu 70:Menu 71:Menu 73:Installer information = Code = 7890, Name = Installer, Servicetelephone number = Call Engineer, no telephone numberPA response = AudibleLine Fault response = AudibleAllow Zone omits = DisabledSystem reset = Customer (PA reset = Customer)Serial Port = PrinterMiscellaneous Options:Access Code = 4 Digit,First Circuit = Re-arm,Alarm Abort = Disabled,Alarm Confirm = Disabled,Dual Ply Entry = Disabled,Day Tamper Comms = Disabled,Set No Mains = Disabled,Reset No Mains = Disabled,Need Lid Open = Enabled,Inhibit Set LED = Enabled,Battery Test = disabledProgram CommunicationsCommunications options:Dial Type = Loop Disconnect,Call Mode = DisabledDownloader Options:Account Name = (blank),Rings to Answer = 5,Answer on 1 ring = disabled,Secure Callback = disabled,P01 to P03 Download Numbers = (blank)When the installer resets defaults using the RST pins, the system changesthe following items:Installer Code 7890User Code 1234Working With The system can be connected to a remote PC using the built in modem overthe telephone network. The remote PC can run to examineand modify the programming of the system. To prepare the system forthis function:496339 Issue 4 25 of 44