9x5xKeypad Display Printed (9853 only)* MeaningComms Fail Comms Fail Communications failure (e.g. noresponse from ARC)Config Changed Config Changed System configuration (site-specificdata) has changedDefaults Loaded Defaults Loaded Default values loaded for allcommandsEEPROM Fail EEPROM Bad Data Control unit memory damagedExp == Tamp Rst Exp. Tamper Restore Expander tamper resetExp == Tamper Exp. Tamper Expander tampered withExpander == Miss Expander Missing Expander disconnectedExpander == Rstr Expander Restored Expander reconnectedF== Missing Forbi Missing F== Forbikobler keypad disconnectedF== Restore Forbi Miss Restore F== Forbikobler keypad reconnectedF== Tamper Forbi Tamper F== Forbikobler keypad tampered withFire Reset U== Fire Reset Fire alarm resetFire Z== Alarm Fire Z== Fire alarm on zone ==Fire Z== Rstr Fire Restore Z== Fire alarm on zone == restoreForbi I/F Tamper Forbi I/F Tamper Forbikobler interface tampered withForbi Lp Tamper Forbi Lp Tamper Forbikobler loop tampered withFr K== Alarm K/P Fire K== Fire alarm started at keypad ==Frb I/F Tamp Rst Forbi I/F Tamp Restore Forbikobler interface tamper resetFrb Lp Tamp Rst Forbi Lp Tamp Restore Forbikobler loop tamper resetGlobal T.Restore Global T.Restore Global zone tamper alarm resetGlobal Tamper Global Tamper Global zone tamper alarmK== Excess Keys Tamper Usercode K== Incorrect access code entered morethan four times at keypad ==K== Missing K/P Missing K== Keypad == disconnectedK== Restore K/P Miss Restore K== Keypad == reconnectedK== Tamper Tamper K/P K== Keypad == tampered withKey Box Cls Z== Keybox Close Z== Keybox on zone == closedKey Box Opn Z== Keybox Open Z== Keybox on zone == openKey Sw Set # Key Switch Set # System set by keyswitch onlevel/partition #KeySw Unset # Key Switch Unset # System unset by keyswitch onlevel/partition #Lid Tamp Restore Lid Tamp Restore Control unit lid tamper resetLid Tamper Lid Tamper Control unit lid tampered withLow Bat Z== Tx Lo Batt Z== Low battery detected on transmitter ==Low Bat Z== Rstr Tx Lo Batt Restore Z== Low battery reset on transmitter ==Low Batt Rstr Low battery Restore Low battery detected on control unitLow Batt Rstr Z== Low Batt Rstr Zone Z== Low battery reset on control unitMd K== Alarm K/P Medi K== Medical alarm started at keypad ==Override # Override # Fault overridden in level/partition #PA K== Alarm K/P PA K== Panic alarm started at keypad ==72 of 76 Issue 1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!