9x5xCommunicatorConnecting the CommunicatorThe control unit has an internal communicator on its main PCB. This is anauto-dialling modem. The baud rate can be set using Command 111.If necessary, a standalone communication device can be connected througha wiring harness to interface pins on the main PCB (this is known as a plugbycommunicator). The control unit can also be fitted with a plug-oncommunicator, plugged directly onto two connectors on the main PCB.The communicator can be used for:• Transmitting alarm signals to alarm receiving equipment at a centralmonitoring station using Scancom Fast Format, Scancom SIA(<strong>Security</strong> Industry Association) or Contact ID (set with Command 103).• Connecting to a PC based at a remote engineering centre. Using<strong>Scant</strong>ronic Downloader software, the remote PC can upload anddownload system parameters (including the event log anddiagnostics), set and unset the alarm system, and carry out otherspecial functions.Telephone LineIdeally, the internal communicator should be connected to an ex-directoryline used exclusively for alarm communications.If an exclusive line is not available and other apparatus is connected to theline (for example, an answer machine), the internal communicator provides aseries connection with line divert for the other apparatus. When triggered, thecommunicator seizes the line and disconnects the other apparatus. Whenthe communicator shuts down, it reconnects the other apparatus.Three-way CallingThe control unit provides a three-way calling facility to make sure the internalcommunicator can always use a shared telephone line.To use this facility, the local exchange must provide the three-way callingservice on the customer's line.Line Monitoring for the Internal CommunicatorThe control unit provides a line monitoring function to check that a telephoneline connected directly to the panel is working, and to indicate a line failure ifit is not. While enabled, this function continually checks the line voltage toensure that the line is connected. If it detects a failure, the system gives theLine Fault Response selected with Command 106.Test CallsThe control unit can be programmed to make test report calls to an ARC."Static" test calls can be programmed to occur at set times or intervals.30 of 76 Issue 1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!