9x5xThe wiring resistance of the cable to the detector (including joints) should notexceed 100 ohms. The recommended maximum cable length within a zoneis 200–300m.4K72K2 EOLAlarm contactsZone 1Tamper contacts124K7Zone 22K2 EOLAlarm contactsTamper contacts4k7YellowVioletRed2k2RedRedRedGoldGoldFigure 18. FSL ConnectionsEOL ConnectionsEach EOL zone is a two-wire closed loop that uses a single 2K2 resistorfitted in series with the alarm contacts to differentiate between "Circuit" and"Tamper" signals. Figure 19 shows how to connect two EOL detectors toadjacent zones. Each detector is wired in series with a common anti-tampercircuit, which is connected to the terminals marked "3" and "4". You mustconnect a single 2K2 resistor in series with the anti-tamper circuit.Issue 1 23 of 76