95EN, 85EN, 65ENConnecting to the Mains SupplyCAUTION: ENSURE THAT THE MAIN SUPPLY IS DISCONNECTED ANDISOLATED BEFORE MAKING ANY MAINS CONNECTIONS.All mains electrical connections must be carried out by a qualified electricianand must comply with the current local regulations (e.g. IEE). The supplymust be fed from an un-switched fused spur fitted with a 3A fuse.The mains supply is connected to a 3-way "Euro Type" fused terminal block(see Figure 30). Ensure that the earth wire is longer than the live and neutralto ensure that the earth is the last to take any strain.To Control PanelTransformer315mA(L)PN230VacFigure 30. Mains ConnectionsNote: To avoid mains interference, the mains cable must enter the controlpanel through its own cable entry hole (see Figure 4) and must not bemixed with other cables.The mains cable must be anchored down with a strain-relief tie. There is aeye located to the top-left of the mains cable entry hole for this purpose.38 of 72