9x5xProgramming OutputsControl unit panel outputs can be programmed using the commands shownin the table below. Open collector outputs are of a "pull down" type thatprovides negative-applied control signals; the system adjusts the outputpolarity when you select the output type.OutputTypeCommandOP1 voltage-free relay 81OP2 voltage-free relay 82OP3 open collector 83OP4 open collector 84OP5 open collector 215OP6 open collector 216OP7 open collector 217OP8 open collector 218Note: Outputs 5 to 8 are taken from the plug-by communicator (see page35).Figure 26 shows some examples of applications for open collector outputs(OP3 is used in these examples).Shock Sensor ResetBell Follow Buzzer/RelayVIPER0VOP3BUZZER/RELAYOP3+ve+ve 12V Aux+ve 12V AuxUse Command 83 4Use Command 83 0Relay energises/buzzer soundswhen bell activates.French Siren TestPIR Set Latch/Walk TestSIREN0VOP3PIROP3+veUse Command 83 10(for use in France only)STFor:Set Latch use Command 83 3Walk Test use Command 83 5Figure 26. Wiring Examples for Open Collector OutputsIssue 1 29 of 76