46044618/9Set switches 1 to 8 to the site code of the 4618/9. Set switches 9 to 10 to thedevice number. The alarm channel triggers odd numbered zones. Thetamper channel triggers even number zones. For further information refer tothe 4618 Installation Guide.Figure 11. Coding for 4618/9 modes 9-13 and 194611/4613Not compatible.4612Set switches 1-10 to the site code of the 4612. The tamper channel triggerschannel B. The alarm channel triggers channel A.The 4612 must be in 2-channel mode. For further information refer to the 4612 Installation Guide.4660/75Refer to the appropriate installation manual.Switching OnAfter coding switch on the battery. Find switch 2 of the small black 2-way DILswitch (marked BATT). Set to ON using a terminal screwdriver or ball pointpen. The transmission LED lights and the unit transmits an open tamperalarm as the case is open. If your unit shows low battery operate backtamper switch five or six times at five second intervals. The sixth and subsequenttransmissions should give a normal transmission.16 of 34 496372 Issue 1