9x5xBacklightWhen supplied from the factory, the control unit is configured with thebacklight On. To turn the backlight Off, remove the jumper from the "ONBACKLIGHT" link, shown in Figure 15.Connecting SoundersFigure 16 and the following tables show the wiring required to connect theexternal sounder (bell box) and optional internal sounders.Note: If a 2k2 resistor is fitted at the tamper return (TR) terminal at the bellbox, use Command 59 to select this EOL mode of termination.Note: The ST terminal on the control panel PCB is the Siren Test output forFrance only. Do not connect it to the strobe input on the external sounder.See Command 81 in the Programming Guide and the output wiring exampleson page 29.To Bell Box6-coreNO (OP1)C (OP1)NO (OP2)C (OP2)TRInternal Sounder16 Ohm Loudspeaker(2 Max. in parallel)LS12V0VFigure 16. Sounder ConnectionsLyntech Ltd - 120 LED/120 lexonControl PanelTerminalsNO(OP1)NO(OP2)Bell-BoxTerminalsTR 12V 0VTRG STRB HOLD +20 of 76 Issue 1