11.07.2015 Views

Cooper TP Workshop Manual_Scant:Layout 1 7/8 ... - Cooper Security

Cooper TP Workshop Manual_Scant:Layout 1 7/8 ... - Cooper Security

Cooper TP Workshop Manual_Scant:Layout 1 7/8 ... - Cooper Security

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

95EN, 85EN, 65ENSettings Defaulted Grade2(Grade 3)Default ValueEng 45 General Configuration01 Common Prtn ON/OFF OFF02 Bell is an SAB/SCB SAB03 View Alms Unset/P.Set Unset04 Engineer/User Authorised Engr05 On-Line Enabled/Disabled Enabled06 Unset/Set First Unset07 Digi Normal/Inverted Normal08 Chime Audible/Visible Audible09 <strong>Manual</strong>/Automatic Omits <strong>Manual</strong>10 Omit Tampers Yes/No No11 Global/Local Setting Global12 Global/Local Unsetting Global13 24hr Omit Global/Local Global14 Prtn/Global Bell Time Prtn15 Latching/Nonlatching Fire Latching16 Timed/Latched code o/p Timed17 Latching/Nonlatching 24hr Latching18 Access code only/all Code only19 NVM locked/unlocked Unlocked20 Unshunt no exit/ &exit No exit21 Ignore/View exit errors Ignore22 Mimic all times/set only All times23 Lo/Hi <strong>Security</strong> Eng Lo24 Duress allow No/Yes NO25 Keypad PA ON/OFF OFF26 Exit/Instant Set Foyer Exit27 Unset Entry Partitions/All All28 Radio PA Silent/Audible AudibleEng 46 DD24301 Confirmation ON/OFF ON02 Sounders on Unconf/Conf Unconfirmed03 Bells on Unconf/Conf Unconfirmed04 After Entry No/Yes No05 Ent KPD Lock ON/OFF OFF06 Confirm 2/1 Zones 2 ZonesEng 47 EN5013101 4/6 Digit Codes 4 (6)02 Internal/Local Sounder Internal03 Instant/Delayed Alarm Instant04 Tampers As Alarm/Tamper Alarm05 General Fault: User/Eng User06 Tcmd Override Yes/No No07 4k4=Masking/Fault Fault08 Mask Override/Inhibit Override9 Mask Unset Flt/Alm/Tamp Fault10 Mask Set Flt/Alm/Tamp Alarm11 AC Fail: No Rst/User/Eng User12 AC Bypass: Always/Usr/Eng Always13 Line Fail: No Rst/User/Eng User14 L F Bypass: Alwys/Usr/Eng Always15 Sup Fail Tamp/Alarm/Alert Alert (Tamper)16 Reset Sup: Eng/Usr/Always User (Eng)17 Reset Jam: Eng/Usr/Always User (Eng)Eng 48 Autoset TimesSet times 1, 2 & 3 00:00Unset times 1, 2 & 3 00:00Timers operate onNo daysPartitions assignedNoneEng 51 Downloader01 Serial Number Blank02 Account Name Blank03 Access Mode OffSettings Defaulted Grade2(Grade 3)Default Value04 Call Back No.1, 2, 3, 4 Blank05-1 Rings to Answer 5 rings05-2 Baud Rate 120005-3 Answer Phone Defeat DisabledEng 52 DigiCom01 Comms Format Disabled02 ARC Nos. 1, 2, 3 Blank03 Account Nos. 1, 2, 3 Blank04 Dialling Mode Consecutive05-01 Restore Signals Enabled05-02 Fast Format 8 FF Channels05-03 Line Fault Enabled06 CID/SIA Reports FullEng 53 RS232 (Not 65EN/85EN)01 Baud Rate 3840002 Remote Modem DisabledEng 60 Starting a CallbackCallback 01 to 04BlankEng 71-76 Custom TextReset MessageCALL ENGINEER TORESET SYSTEMLocation TextPANEL LOCATIONTEXT NOT SETUPPrinter Title (not 65EN) SCANTRONIC 5SERIESRemote Reset MsgRING A.R.C FORREM. RESET CODEBanner TextBlankPartition TextBlankNotes:1. The control unit ignores thistimer until the user accesses themenu. Once the user selects themenu the display shows 4 hoursand the timer starts from there on.2. For Grade 3 requirements, youmay need to enable the Maskingattribute on specific zones.3. There are various options thatyou can select and still comply, forexample: Final Exit,Exit Terminate,or Lock Set.4. 21 is the lowest algorithm thatgenerates 6 digit reset codes forGrade 3 requirements.49 of 72

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!