4600IntroductionThe 4600 electronic intruder alarm system is a fully programmable, 8-zone,bells only, radio security system, designed for domestic installations and tocomply with BS 6799, Class 3.The system comprises a main control panel, which is hard-wired to anexternal bell/strobe, together with detector/transmitters, which are wire-freeand communicate with the main control panel by means of radio signals.Technical SpecificationElectricalInput supply voltageShort-circuit protectionReverse polarity protectionBattery back-upAuxiliary outputDimensionsWeightHumidityOperating temp.= 225-253VAC, 50Hz, Max 30VA.= Outputs short-circuit protected for indefiniteperiods by means of Polyswitches which willrecover after removal of short-circuit.= Battery connections are reverse polarityprotected for at least 5 minutes.= Back-up time, panel only with fully chargedbattery, typically 20 hours 12V Lead Acidbattery, typically 2.1AH. Float charge voltage13.7V typically. Charge time for flat battery,maximum 14 hours, typically 6 hours.= 13.7VDC. Continuous current available200mA. Maximum short term current 1A forup to 20 minutes.= h x w x d 160 x 257 x 72 mm.= 1.2 kg.= 80° RH.= -10° to + 55° C2 of 12 496368 Issue 1