770rDipswitches1. OFF = IR Learning disabled.Radio Learning enabled.ON = IR Learning enabled.Radio Learning disabled.2. OFF = Module takes no action if jamming detected.ON = Module signals trouble when jamming detected.3. OFF = Module takes no action if detector missing.ON = Module signals trouble if no transmission received from detectorfor period set by Dipswitch 4.4. OFF = Supervision period = 3 hours.ON = Supervision period = 20 mins.5. OFF = Input 1 and 2 wiring = End of Line resistor.ON = Input 1 and 2 wiring = closed circuit.6. OFF = Input 1 is Normally Closed.ON = Input 1 is Normally Open.7. OFF = Input 1 is Momentary.ON = Input 1 is Latched.8. OFF = See Modes 1, 2 and 4.ON = See Modes 1, 2 and 4.Output JumpersIf required, you can connect the common output terminal of each of the wiredoutputs to either the +ve or -ve supply. The block of jumpers marked 9 inFigure 2 controls the polarity of the common output terminals for each of thewired outputs 1 to 4. For example, for output 1:Common terminal is 12VDC.Common terminal is 0VDC.Output is voltage free.DisplaysThe column of LEDs in the centre of the PCB acts as the main programmingdisplay. In Mode 1 the LEDs can also display the transmission of channelsignals from the module.6 of 30 Issue 1